Description

Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).

To use this subcommand, you must have the Login User privilege.

Synopsis

racadm getled -m <module>

Input

CMC only options:

-m <module> — Specifies the module whose LED settings you want to view.

<module> can be one of the following:

  • server-n where n=1–4
  • switch-n where n=1
  • chassis
  • cmc-active

Example

For CMC:

  • racadm getled -m server-10

    <module> <LED state> server-10 Blinking

  • racadm getled -m chassis

    <module> <LED state> server-10 Not blinking

  • racadm getled -m server-1

    <module> <LED state> server-1 ON

  • racadm getled -m server-9

    <module> <LED state> server-9 Extension(1)