Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Chassis Management Controller Version 3.10 for PowerEdge VRTX RACADM CLI Guide

PDF

fwupdate

Table 1. Details of fwupdate. The following table provides the details of the fwupdate attribute:
Description
Allows you to update the firmware on the active and standby CMC firmware, chassis infrastructure firmware, and storage component firmware (RAID controller, hard disk drive, and expander). You can:
  • Check the firmware update process status.
  • Update the firmware from a FTP or a TFTP server by providing an IP address and optional path.
  • Update the firmware from the local file system using remote RACADM.
  • The subcommand updates one or more devices of a single type at a time.

To use this subcommand, you must have the Chassis Configuration Administrator privilege.

  • NOTE:
    • Running the subcommand to update the active CMC firmware resets the CMC, causing all network connections to get logged off. While updating all other modules, including the standby CMC, the active CMC continues to function normally without resetting.

    • The subcommand generates an error, when used on the extension slot of a multi-slot server.

    • The CMC firmware cannot be updated to any earlier version other than 2.0 for a chassis that is configured with 1600W PSU.

    • CMC firmware update or roll back is supported only for firmware versions 1.2, 1.25, 1.3, 1.31, 1.35, 1.36, 2.0, and later. For any version other than these, first update to any of these versions, and then update to the required version.

For 13th generation and later, CMC firmware includes a signature which is verified by CMC before update to ensure the authenticity of the uploaded firmware. The firmware update process is successful only if the firmware image is authenticated by CMC to be a valid image from the service provider and has not been altered. The firmware update process is stopped if CMC cannot verify the signature of the uploaded firmware image.

Upload firmware image from TFTP server and start firmware update.

  • NOTE: Run the firmware update command through only one remote racadm session at a time.
Synopsis
  • Using Remote RACADM:
    racadm -r fwupdate -p -u -d <
                                                          firmware image>
                                                       
    • NOTE: iDRAC7 targets are not supported from CMC. Use the CMC GUI to update iDRAC7 targets from CMC.

    When using FTP, if you provide the full path to the image file on the CLI, then the CMC uses that path to locate that file on the host. If you do not provide a full path, then the CMC searches the home directory of the specified user for the file if the host system is running Linux or another variant of UNIX. If the host system is running Windows, then a default folder, such as C:\ftproot is searched.

    • NOTE: While performing firmware update using the racadm fwupdate command, if the number of characters in the firmware image path is greater than 256 characters, Remote RACADM session logs off with the error message ERROR: Specified path is too long.
  • racadm fwupdate -g -u -a 192.168.0.100 -d firmimg.cmc -m cmc-active
Input
  • NOTE: Firmware update from local RACADM (using the -p, -u, or -d options) is not supported on Linux operating system.
  • -p — The -p option is used to update the firmware file from the client. The -u option must be used with the -p option.
  • -f — The FTP is used to download the firmware.
  • -g — For CMC, the firmware is downloaded using the TFTP server.
  • -u — The firmware update operation is performed.
  • -a — Specifies the TFTP server IP address or FQDN used for the firmware image (used with -g).
    • NOTE: CMC accepts IPv4, IPv6, or fully qualified domain names (FQDN) for both FTP and TFTP servers.
  • -d — Specifies the source path where the firmware image is stored.
    • NOTE: The default source path is local Default: Designated TFTP default directory on that host for the file if -g option is absent. If -g is used, it defaults to a directory configured on the TFTP server.
  • -o — Turns off the servers to perform an update.
  • -m < module >—

    Specifies the module or device to be updated. < module > is one of the following values:

    • NOTE: You can also specify multiple modules: –m <module 1> –m <module 2>, and so on.
    • cmc-active (default)
    • cmc-standby
    • iominf-n, where n = 1
      • NOTE: You can specify the cmc-active and cmc-standby modules at the same time along with one or more server-n modules. This enables the devices to be updated together.
    • main-board
    • perc-fqdd, where fqdd is FQDD of the PERC
    • expander-fqdd, where fqdd is FQDD of the Storage Expander
    • hdd-fqdd, where fqdd is FQDD of the HDD
  • -s — Displays the current status of the firmware update.
    • NOTE: Use -m to display the status of the module update. Omit -m to display the status of the active CMC update.
    • NOTE: Use all to get the status of all the targets that must be updated.
  • -c — Cancels the current firmware update of a module.
    • NOTE: The Enclosure, Expander, HDD, and PERC updates cannot be cancelled.
Output

Displays a message indicating the operation that is being performed.

Example
  • NOTE: The following commands specifically apply to an active-CMC update.
  • Upload a firmware image from the client and start firmware update:
     racadm fwupdate -p -u -d vrtx_cmc.bin 
  • Upload the firmware image from the TFTP server and start the firmware update:
     racadm fwupdate -g -u -a 192.168.0.100 -d vrtx_cmc.bin  -m cmc-active
    TFTP firmwareate has been initiated. This update process may take several minutes to complete.
  • Upload the firmware image from the FTP server and start the firmware update.
    racadm fwupdate -f 192.168.0.100 fred password123 -d vrtx_cmc.bin  -m cmc-active
  • Start IOM infrastructure firmware update.
    racadm fwupdate -u -m iominf-1
  • Update firmware on both the CMCs.
    racadm fwupdate -g -u -a 192.168.0.100 -d vrtx_cmc.bin  -m cmc-active -m cmc-standby

Signed CMC Firmware Image:

  • racadm fwupdate –g –u –a <TFTP IP> -d <Firmware Path> -m cmc-active

    Firmware update has been initiated. This update process may take several minutes to complete.

  • racadm fwupdate –s –m cmc-active

    Invalid firmware: The uploaded firmware image does not contain a verification signature


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\