Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

iDRAC 8/7 v2.70.70.70 RACADM CLI Guide

PDF

RACADM Proxy

Table 1. Details of RACADM ProxyThe following table provides the details of RACADM Proxy attribute:
Description

On the PowerEdge FX2/FX2s systems, you can manage the compute sleds and CMC using the iDRAC’s RACADM Proxy feature that redirects commands from iDRAC to CMC. You can return the CMC response to local or remote RACADM.to access the CMC configuration and reporting features without placing the CMC on the management network. The CMC configuration commands are supported through local proxy when local configuration is enabled on iDRAC.

NOTE: : Local racadm and local racadm proxy runs with root user privilege.

Synopsis

Local RACADM proxy usage

racadm <CMC racadm subcommand> --proxy

Remote RACADM proxy usage

racadm <CMC racadm subcommand> -u <username> -p <password> -r <idrac-ip connected to cmc> --proxy

NOTE: :

  • The attribute racadm getconfig -g cfgractuning -o cfgRacTuneChassisMgmtAtServer must be set as non-zero in CMC.
  • The attribute racadm get system.ChassisControl.ChassisManagementMonitoring attribute must be enabled in iDRAC.
  • --proxy must be entered at the end of the command.
  • Table 2. The root privilege is the default privilege for Local RACADM proxy.See the following table:
    Required CMC Privilege for an operation Required iDrac Privilege for proxy operation

    CMC Login User

    Login

    Chassis Configuration Administrator

    Configure

    User Configuration Administrator

    Configure User

    Clear Logs Administrator

    Logs

    Chassis Control Administrator

    System Control

    Server Administrator

    System Control

    Test Alert User

    System Operations

    Debug Command Administrator

    Debug

    Fabric x Administrator (where x is A, B, or C)

    System Control

    The user privilege in the Remote RACADM proxy for CMC maps to iDRAC privilege.
  • When CMC is not placed on the network, the import, export, and file operation commands to CIFS, NFS, or FTP will fail.
  • When the Remote or Local RACADM Proxy operation is in progress, if the iDRAC is reset, then the Proxy operation fails and the output is not displayed in Remote or Local RACADM.
  • When racadm getsystem.ChassisControl.ChassisManagementMonitoring attribute is set to monitor, all the users including root users can only view the attribute.

    To configure, set the attribute to monitor and manage in CMC.

Input
  • -u — Specifies the user name of the remote share that stores the catalog file. 
  • -p — Specifies the password of the remote share that stores the catalog file.
  • -r — Specifies the iDRAC IP address connected to CMC.
Example

Local RACADM

racadm getractime --proxy
Remote RACADM
racadm getractime -u root -p xxx -r 192.168.0 getractime --proxy

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\