Dell Chassis Management Controller Version 6.0 for PowerEdge M1000e User’s Guide

Deactivating FlexAddress

The FlexAddress or feature can be deactivated and the SD card returned to a pre-installation state using a RACADM command. There is no deactivation function within the Web interface. Deactivation returns the SD card to its original state where it can be installed and activated on a different chassis. The term FlexAddress, in this context, implies both FlexAddress and FlexAddressPlus.

NOTE The SD card must be physically installed in CMC, and the chassis must be powered-down before executing the deactivation command.

If you execute the deactivation command with no card installed, or with a card from a different chassis installed, the feature is deactivated and no change is made to the card.

To deactivate the FlexAddress feature and restore the SD card:

racadm feature -d -c flexaddress
The command returns the following status message if it is successfully deactivated:
feature FlexAddress is deactivated on the chassis successfully.
If the chassis is not powered-down prior to execution, the command fails with the following error message:
ERROR: Unable to deactivate the feature because the chassis is powered ON

For further information on the command, see the feature command section of the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide.