Configuring BFD and UFD for VXLAN

For controller-based VXLAN, you can optionally configure BFD and UFD for more resiliency. To configure BFD and UFD, follow these steps:

  1. Enable BFD globally.
    CONFIGURATION mode
    bfd enable
    Enter the result of your step here (optional).
  2. Create an uplink-state group.
    CONFIGURATION mode
    uplink-state-group group-id
    group-id: values are from 1 to 16.
  3. Assign a VLT port channel to the uplink-state group as an upstream link.
    UPLINK-STATE-GROUP mode
    upstream interface
  4. Assign a network port or port channel to the uplink-state group as a downstream link.
    UPLINK-STATE-GROUP mode
    {upstream | downstream} interface