Hot-plugged PCIe SSDs not detected

Description
Removing all PCIe SSDs connected behind a particular PCIe Extender and performing a warm reboot may cause iDRAC to not detect subsequent hot-plugs on that extender.
Workaround
With the hot-plugged drive(s) still in the system, perform a cold reboot of the host.
Systems affected
All system supported by this release.
Tracking number
116735