Computer environment
Airborne contaminant level: G1 as defined by ISA-S71.04-1985
Table 1. Computer environmentThe following table provides your computer environment information.
|
Operating
|
Storage
|
Temperature range
|
-29°C to 63°C (-20.2°F to 145.4°F)
|
-51°C to 71°C (-59.8°F to 159.8°F)
|
Relative humidity (maximum)
|
10% to 80% (non-condensing)
NOTE: Maximum dew point temperature = 26°C
|
10% to 95% (non-condensing)
NOTE: Maximum dew point temperature = 33°C
|
Vibration (maximum)
|
Vertical
|
- 1.04 GRMS
- 0.20 GRMS
- 0.74 GRMS
|
- 2.24 GRMS
- 1.45 GRMS
- 1.32 GRMS
|
Transverse
|
Longitudinal
|
Shock (maximum)
|
40 G†, 11 ms, saw-tooth, 3 shocks +/- per axis, 3 axes
|
185 G‡, 2 ms half sine; 2 shocks/axis/direction for a total of 12 shocks
|
Altitude (maximum)
|
Chamber at 15,000 ft for 1 hour
|
Chamber at 30,000 ft for 1 hour
|
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse when the hard drive is in use.
‡ Measured using a 2 ms half-sine pulse when the hard-drive head is in parked position.