OpenManage Integration for VMware vCenter Version 5.0 User's Guide

Chassis inventory fails in OMIVV after promoting backup lead as a lead

When the lead chassis of the MCM group is powered off or not functional, the backup lead gets promoted as the lead chassis. In this case, inventory of the lead and member chassis fails in OMIVV.

Resolution: Perform the following:
  1. Make the previous lead chassis active and run the inventory from OMIVV.
  2. Delete the chassis credential profile and all the chassis present in the group from OMIVV.
  3. Add the new lead chassis to rediscover the group.

Version Affected: 5.0