Dell PowerEdge C6320 Owner's Manual

Installing the control panel

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
NOTE: Observe the routing of the cable on the chassis as you remove them from the system. You must route these cables properly when you replace them to prevent the cables from being pinched or crimped.
NOTE: Additional tape maybe required to secure the cables.
  1. Follow the safety guidelines listed in the Safety instructions section.
  2. Follow the procedure listed in the Before working inside your system section.
  3. Remove the control panel.
  4. Keep the Phillips #1 screwdriver ready.

Steps

  1. Connect the control panel cable to the control panel.
  2. Push aside the retention hooks on the control panel assembly and place the control panel into the control panel assembly.
  3. Install the control panel assembly into the hard drive cage.
    Figure 1. Installing the left side control panel
    This image shows installing the left side control panel
    Figure 2. Installing the right side control panel
    This image shows installing the right side control panel
  4. Install the screws that secure the control panel assembly to the hard drive cage.
  5. Install the screws that secure the control panel assemblies to the chassis.

Next steps

  1. Install the hard drive cage into the enclosure.
  2. Connect all the cables to the backplane.
  3. Connect the control panel cables to the power distribution board.
  4. Install all the removed hard drives.
  5. Follow the procedure listed in the After working inside your system section.