Dell PowerEdge RAID Controller S140 User’s Guide

BSOD is observed while booting on the NVMe configuration server

Description:
NVMe drives utilize the system resources, if more number of NVMe drives is connected to a server having less number of cores, then there is a lack of resources to service the NVMe and BSOD can occur.
Corrective action:
Ensure logical processor is enabled under BIOS HII > Processor Settings or remove some of the NVMe drives before booting and hot insert the drives after booting.