From the NIC Card drop-down
menu, select the NIC port that you want to configure.
NOTE:
You can use only one NIC at a time to communicate with the network.
Modular servers support maximum of 4 ports.
From the IPV4 Network Settings→
IP Address Source drop-down menu, select one of the following
options:
No Configuration — indicates
that the NIC must not be configured.
DHCP — indicates that
the NIC must be configured using an IP address from a DHCP server.
If DHCP is selected, a DHCP IP address is displayed on the Network Settings page.
Static IP — indicates
that the NIC must be configured using a static IP. Type the IP Address Properties — IP Address, Subnet Mask, Default Gateway, and DNS Address. If you do not have this
information, contact your network administrator.
From the IPV6 Network Settings→
IP Address Source drop-down menu, select one of the following
options:
No Configuration — indicates
that the NIC must not be configured.
DHCPv6 — indicates that
the NIC must be configured using an IP address from a DHCPv6 server.
If DHCPv6 is selected, a DHCPv6 IP address is displayed on the Network Settings page.
NOTE: While configuring DHCP server
with IPv6, the configuration fails if you disable forwarding or advertising
options.
Static IP — indicates
that the NIC must be configured using a static IP. Type the IP Address Properties — IP Address, Subnet Mask, Default Gateway, and DNS Address. If you do not have this
information, contact your network administrator.
Click Enabled and type
the VLAN ID and Priority under Lifecycle Controller VLAN Settings to
configure the VLAN settings of a NIC.
You cannot configure the VLAN settlings of the following
NICs:
Emulex SeaHawk-2 (FH) PCIe Adapter
Emulex SeaHawk-2 (LP) PCIe Adapter
Emulex Vindicator-2 rNDC
Emulex Sea Stallion-2 Mezzanine Card
Emulex Pave Low-2 bNDC
Emulex SeaHawk-2 (FH) NIC Only PCIe Adapter
Emulex SeaHawk-2 (LP) NIC Only PCIe Adapter
Emulex Vindicator-2 NIC Only rNDC
Emulex Sea Stallion-2 NIC Only Mezzanine Card
Emulex Pave Low-2 NIC Only bNDC
Click Next.
NOTE: If Lifecycle Controller settings are not correctly configured, an
error message is displayed.
NOTE: If you are unable to
connect to a network, verify the settings. For information about correct
network settings, contact your network administrator.