Dell Shared PowerEdge RAID Controller 8 Cards For Dell PowerEdge VRTX Systems User’s Guide

Replacing a Shared PERC 8 Internal card

When replacing an existing Shared PERC 8 Internal card in the PowerEdge VRTX system, perform the following steps to ensure proper functionality of the shared storage after the replacement process is complete.
  1. Prerequisites for removing the Shared PERC Internal card. See Prerequisites for removing the Shared PERC 8 Internal card .
  2. Remove the Shared PERC Internal card. See Removing the Shared PERC 8 Internal card .
  3. Install the Shared PERC Internal card. See Installing the Shared PERC 8 Internal card .
  4. Postinstallation tasks for the Shared PERC Internal card. See Postinstallation tasks for the Shared PERC 8 Internal card .
  • CAUTION: Shared PERC 8 Internal cards are not hot-swappable. Do not remove or install Shared PERC 8 Internal cards from the system board while the PowerEdge VRTX system is powered on.

In the Single Shared PERC 8 Internal card configuration, the shared PERC slot is labeled as PERC1 on the PowerEdge VRTX system board. In the Fault Tolerant Shared PERC 8 Internal card configuration, the shared PERC slots are labeled as PERC1 and PERC2 on the PowerEdge VRTX system board. To locate the Shared PERC slots, see System Board Connectors in the Dell PowerEdge VRTX Enclosure Owner's Manual at Dell.com/poweredgemanuals.

Controller firmware package 23.8.10-0059 is the minimum firmware package version required for fault tolerant Shared PERC 8 Internal card configurations on PowerEdge VRTX.

  • NOTE: Write-back caching in a fault tolerant configuration is not supported with firmware version 23.8.10-0061 and the earlier versions.
  • NOTE: For write-back caching capability, ensure that all the storage solution components are updated with the latest firmware.

For more information, see the storage subsystem compatibility matrix document at Dell.com/support/home.

For information on removing and reinstalling system parts, see the VRTX Enclosure Owner's Manual of the system at Dell.com/poweredgemanuals.