The following issues related to the user interface are fixed in Storage Center 7.3:

Table 1. User Interface Issues Fixed in Storage Center 7.3.11Fixed issues in Storage Center 7.3.11 related to the user interface
Issue Description
SCOS-52572 In rare instances, the Dell Storage Manager Client might incorrectly display a LiveVolume as a replication, if the LiveVolume is mapped to a cluster with many servers.
SCOS-51215When an iSCSI interface is removed from a Storage Center fault domain, the IP address on the iSCSI interface is not released.
SCOS-50682SC460 or SCv360 expansion enclosure settings are not being displayed correctly in the Dell Storage Manager Client and Unisphere web interface.
SCOS-48963When the minimum password age requirement is enabled on a Data Collector, attempting to change the password results in a command failure if the password does not meet the Minimum Age setting.
SCOS-44778If NTP is not configured on a Storage Center, a mismatch in the clocks between the controllers might prevent users from logging into Storage Center using the Dell Storage Manager Client or Unisphere web interface.
Table 2. User Interface Issues Fixed in Storage Center 7.3.2Fixed issues in Storage Center 7.3.2 related to the user interface
Issue Description
SCOS-49176 For SCv2000, SCv2020, SCv2080, and SC4020 storage systems and legacy SAS enclosures, when the Storage Manager Client is directly connected to a Storage Center, the Request DC Undervoltage Clear command fails to clear the undervoltage indicator.
Table 3. User Interface Issues Fixed in Storage Center 7.3.1Fixed issues in Storage Center 7.3.1 related to the user interface
Issue Description
SCOS-41051 When the Storage Manager Client is connected to a Storage Center through a Data Collector, the Storage Manager Client does not allow you to change the name of an enclosure and asset tag.
SCOS-25031 After a controller failover, the peer controller might be reported as down by both SNMP and a Storage Manager Client that is directly connected to the peer controller.
SCOS-14951 After deleting volumes and snapshots, Storage Center does not immediately report the deleted volume space as free space for a disk folder.