show rmon hc-alarm

Display the contents of RMON High-Capacity alarm table.

Syntax show rmon hc-alarm [ index] [brief]
Parameters
index (OPTIONAL) Enter the table index number to display just that entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON High-Capacity alarm table in an easy-to-read format.
Defaults none
Command Modes EXEC
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Example (Index)
Dell#show rmon hc-alarm 1
                                             RMON high-capacity alarm entry 2
                                             object: 1.3.6.1.2.1.2.2.1.4.2099844
                                             sample interval: 10
                                             sample type: delta value.
                                             value: 0, value status: positive  
                                             alarm type: rising or falling alarm.
                                             alarm rising threshold value: positive.
                                             rising threshold: 500, RMON event index: 3
                                             alarm falling threshold value: positive.
                                             falling threshold: 300, RMON event index: 4
                                             alarm sampling failed 0 times.
                                             alarm owner:
                                             alarm storage type: non-volatile.
                                             alarm status: OK
                                             Dell#
                                          
Example (Brief)
Dell#show rmon hc-alarm brief
                                             index     SNMP OID
                                             ----------------------------------
                                             1         1.3.6.1.2.1.1.3
                                             2         1.3.6.1.2.1.1.3
                                             3         1.3.6.1.2.1.1.3
                                             4         1.3.6.1.2.1.1.3
                                             5         1.3.6.1.2.1.1.3
                                             Dell#
                                          

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"