Dell PowerEdge M1000e Chassis Management Controller Firmware Version 5.1 User’s Guide

PDF

Command Messages

The following table lists the RACADM commands and output for common FlexAddress situations.

Table 1. FlexAddress Commands and Output
Situation Command Output
SD card in the active CMC module is bound to another service tag. $racadm featurecard -s

The feature card inserted is valid and contains the following feature(s)

FlexAddress: The feature card is bound to another chassis, svctag = <Service tag Number> SD card SN = <Valid flex address serial number>

SD card in the active CMC module that is bound to the same service tag. $racadm featurecard -s

The feature card inserted is valid and contains the following feature(s)

FlexAddress: The feature card is bound to this chassis

SD card in the active CMC module that is not bound to any service tag. $racadm featurecard -s

The feature card inserted is valid and contains the following feature(s)

FlexAddress: The feature card is not bound to any chassis

FlexAddress feature not active on the chassis for any reason (No SD card inserted/ corrupt SD card/ after feature deactivated /SD card bound to a different chassis).

$racadm setflexaddr [-f <fabricName> <slotState>]

$racadm setflexaddr [-i <slot#> <slotstate>]

ERROR: Flexaddress feature is not active on the chassis

Guest user attempts to set FlexAddress on slots or fabrics.

$racadm setflexaddr [-f <fabricName> <slotState>]

$racadm setflexaddr [-i <slot#> <slotstate>]

ERROR: Insufficient user privileges to perform operation

Deactivating FlexAddress feature with chassis powered ON. $racadm feature -d -c flexaddress

ERROR: Unable to deactivate the feature because the chassis is powered ON

Guest user tries to deactivate the feature on the chassis. $racadm feature -d -c flexaddress

ERROR: Insufficient user privileges to perform operation

Changing the slot/fabric FlexAddress settings while the server modules are powered ON. $racadm setflexaddr -i 1 1

ERROR: Unable to perform the set operation because it affects a powered ON server


Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\