Unable to complete the operation as there is no response from iDRAC.
Detailed Description
The error is caused due to iDRAC failure.
Recommended Response Action
1) Turn off the system and disconnect the power cord.
2) Wait for five seconds.
3) Reconnect the power cord and turn on the system.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0002
Message
Unable to detect vFlash SD card.
Detailed Description
The vFlash SD Card is either not present or not correctly inserted.
Recommended Response Action
Insert the vFlash SD card or reinsert the vFlash SD card, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0003
Message
Successfully initialized vFlash SD card.
Detailed Description
vFlash SD card was successfully initialized.
Recommended Response Action
No response action is required.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0004
Message
Unable to initialize vFlash SD card.
Detailed Description
The vFlash SD card is incorrectly inserted, the vFlash SD card is faulty, or there is an iDRAC communication failure.
Recommended Response Action
Reinsert or replace the vFlash SD card, or reset iDRAC, and retry the operation. If the problem persists:
1) Turn off the system and disconnect the power cord.
2) Wait for five seconds.
3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0005
Message
Internal error while retrieving update information.
Detailed Description
Internal error while retrieving firmware version for the currently installed components. For more information about the failure,
see Lifecycle Log.
Recommended Response Action
1) Turn off the system and disconnect the power cord.
2) Wait for five seconds.
3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0006
Message
Unable to save vFlash SD card settings.
Detailed Description
If a vFlash SD card is not present in the system or if the card is locked, Lifecycle Controller cannot save the settings.
Recommended Response Action
Insert the vFlash SD card or unlock the vFlash SD card and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0007
Message
Unable to load vFlash SD card settings.
Detailed Description
Lifecycle Controller is unable to retrieve vFlash SD card information from iDRAC.
Recommended Response Action
Reinsert the vFlash SD card and retry the operation. If the problem persists:
1) Turn off the system and disconnect the power cord.
2) Wait for five seconds.
3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0008
Message
Unable to communicate with iDRAC.
Detailed Description
An internal error occurred while communicating with iDRAC.
Recommended Response Action
Exit the wizard and retry the operation. If the problem persists:
1) Turn off the system and disconnect the power cord.
2) Wait for five seconds.
3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0009
Message
Unable to enable vFlash SD card.
Detailed Description
The vFlash SD card is missing or not inserted correctly. iDRAC is not able to enable vFlash SD card.
Recommended Response Action
Reinsert the vFlash SD card and retry the operation. If the problem persists:
1) Turn off the system and disconnect the power cord.
2) Wait for five seconds.
3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0010
Message
Invalid folder name or USB drive not found.
Detailed Description
Operation failed because the folder name entered is incorrect or the USB drive is disconnected.
Recommended Response Action
Enter a valid folder name or attach the USB drive and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0011
Message
Insufficient space to copy the file to the USB drive.
Detailed Description
The USB drive does not have sufficient free space to copy the file.
Recommended Response Action
Make sure the USB drive has sufficient free space before retrying the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0012
Message
Unable to write to the USB drive.
Detailed Description
The USB drive is write protected.
Recommended Response Action
Remove write protection on the USB drive before retrying the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0013
Message
Unable to copy the file to USB drive.
Detailed Description
The USB drive is disconnected or is not readable.
Recommended Response Action
Remove and reinsert the USB drive and retry the operation. If the problem persists, restart the system and retry.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0014
Message
Unable to detect vFlash SD card.
Detailed Description
The import operation failed because the vFlash SD card is missing or disabled.
Recommended Response Action
Make sure the vFlash SD card is inserted and enabled before retrying the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0015
Message
iDRAC not responding.
Detailed Description
iDRAC has encountered a hardware error.
Recommended Response Action
Retry the operation. If the problem persists, 1) Turn off the system and disconnect the power cord.
2) Wait five seconds.
3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC0016
Message
iDRAC communication failure.
Detailed Description
Lifecycle Controller is unable to communicate with iDRAC.
Recommended Response Action
Retry the operation. If the problem persists, 1) Turn off the system and disconnect the power cord.
2) Wait five seconds.
3) Reconnect the power cord, turn on the system, and retry the operation.
Category
Configuration
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1000
Message
The
arg1 is present.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1001
Message
The
arg1 is absent.
Arguments
arg1 = name
Detailed Description
The absent device may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Re-install or reconnect the hardware.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
The <name> is absent. Check hardware
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1002
Message
The
arg1 is disabled.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
If device disabled unexpectedly, re-enable device.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1003
Message
The
arg1 is enabled.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1004
Message
The storage adapter is present.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1005
Message
The storage adapter is absent.
Detailed Description
The storage adapter may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Install storage adapter.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
The storage adapter is absent. Check hardware
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1006
Message
The storage adapter is disabled.
Detailed Description
None
Recommended Response Action
If adapter disabled unexpectedly, re-enable the storage adapter.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1007
Message
The storage adapter is enabled.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1008
Message
The backplane is present.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1009
Message
The backplane is absent.
Detailed Description
The backplane may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
The backplane is absent. Check hardware
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1010
Message
The backplane is disabled.
Detailed Description
None
Recommended Response Action
If disabled unexpectedly, re-enable backplane.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1011
Message
The backplane is enabled.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1012
Message
The USB cable is present.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1013
Message
The USB cable is absent.
Detailed Description
The USB cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
The USB cable is absent. Check cable
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1014
Message
The mezzanine card
arg1 is present.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1015
Message
The mezzanine card
arg1 is absent.
Arguments
arg1 = number
Detailed Description
The mezzanine card may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1100
Message
The
arg1 was installed in slot
arg2 .
Arguments
arg1 = name
arg2 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1101
Message
The
arg1 is removed from slot
arg2 .
Arguments
arg1 = name
arg2 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1200
Message
The sled
arg1 is inserted in slot
arg2 .
Arguments
arg1 = sled name
arg2 = slot number
Detailed Description
The sled identified in the message is inserted in the slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC1201
Message
The sled
arg1 is removed from slot
arg2 .
Arguments
arg1 = sled name
arg2 = slot number
Detailed Description
The sled identified in the message is removed from the slot identified in the message.
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2000
Message
The
arg1 cable or interconnect is connected.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2001
Message
The
arg1 cable or interconnect is not connected or is improperly connected.
Arguments
arg1 = name
Detailed Description
The cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
The <name> cable or interconnect failure. Check connection
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2002
Message
The storage
arg1 cable or interconnect is connected.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2003
Message
The storage
arg1 cable is not connected, or is improperly connected.
Arguments
arg1 = name
Detailed Description
The cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
Storage <name> cable or interconnect failure. Check connection
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2004
Message
The system board
arg1 cable or interconnect is connected.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2005
Message
The system board
arg1 cable or interconnect is not connected, or is improperly connected.
Arguments
arg1 = name
Detailed Description
The cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
System board <name> cable or interconnect failure. Check connection
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2006
Message
The
arg1 is not installed correctly.
Arguments
arg1 = name
Detailed Description
The device may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
<name> is not installed correctly. Check connection
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2007
Message
The
arg1 is installed correctly.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2008
Message
A fabric mismatch detected for mezzanine card
arg1 .
Arguments
arg1 = number
Detailed Description
The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the
fabric type is then set for the CMC and the CMC will ensure that all subsequent IOMs and mezzanine cards match.
Recommended Response Action
Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2009
Message
Mezzanine card
arg1 is installed correctly.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2010
Message
The riser board cable or interconnect is connected.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2011
Message
The riser board cable or interconnect is not connected, or is improperly connected.
Detailed Description
The riser blade cable may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
Check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
Riser board cable or interconnect failure. Check connection
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2012
Message
A fabric mismatch detected on fabric
arg1 with server in slot
arg2 .
Arguments
arg1 = name
arg2 = number
Detailed Description
The fabric type on the server does not match that of the IO module.
Recommended Response Action
Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2013
Message
Fabric mismatch corrected on fabric
arg1 with server in slot
arg2 .
Arguments
arg1 = name
arg2 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2014
Message
A hardware misconfiguration detected on
arg1 .
Arguments
arg1 = name
Detailed Description
None.
Recommended Response Action
Make sure the hardware is installed correctly. Refer to the product documentation for correct configuration and installation
procedures.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
A hardware misconfiguration detected on <name>. Check hardware
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC2015
Message
The
arg1 is configured correctly.
Arguments
arg1 = name
Detailed Description
None.
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC3000
Message
The
arg1 is removed.
Arguments
arg1 = name
Detailed Description
The removed device may be necessary for proper operation. System functionality may be degraded.
Recommended Response Action
If removal was unintended, check presence, then re-install or reconnect
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC3001
Message
The
arg1 is inserted.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC3002
Message
Server
arg1 is removed.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
If removal was unintended, check presence, then re-insert
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC3003
Message
Server
arg1 was inserted.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC3004
Message
IO module
arg1 is removed.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
If removal was unintended, check presence, then re-insert
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC3005
Message
IO module
arg1 was inserted.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC3006
Message
Unable to QuickDeploy server in slot
arg1 .
Arguments
arg1 = slot number
Detailed Description
There are not enough IPv4 addresses reserved for the servers in this chassis. Therefore the newly inserted server could not
be configured with the QuickDeploy feature.
Recommended Response Action
Do the following: 1) Check the number of reserved IPv4 addresses for QuickDeploy. 2) Modify it such that the newly inserted
blade will obtain an IP address for QuickDeploy. 3) Reseat the server to see the QuickDeploy prompt on LCD panel or manually
configure the network parameters for the server.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4000
Message
A hardware incompatibility detected between BMC/iDRAC firmware and CPU.
Detailed Description
A hardware incompatibility was detected between BMC/iDRAC firmware and Processor(s). An iDRAC or BMC firmware update is needed.
Recommended Response Action
Update the BMC/iDRAC firmware. If the problem persists, contact support.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
Incompatibility between BMC/iDRAC firmware and CPU. Update firmware
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4001
Message
A hardware incompatibility was corrected between BMC/iDRAC firmware and CPU.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4002
Message
A hardware incompatibility detected between BMC/iDRAC firmware and other hardware.
Detailed Description
A hardware incompatibility was detected between BMC/iDRAC firmware and other hardware. An iDRAC or BMC firmware update is
needed.
Recommended Response Action
Update the BMC/iDRAC firmware. If the problem persists, contact support.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4003
Message
A hardware incompatibility was corrected between BMC/iDRAC firmware and other hardware.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4010
Message
Hardware successfully updated for mezzanine card
arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4011
Message
Hardware unsuccessfully updated for mezzanine card
arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
Check presence, re-install or reconnect, then re-attempt the update. If the problem persists, contact support.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4012
Message
Hardware successfully updated for embedded NIC.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4013
Message
Hardware unsuccessfully updated for embedded NIC.
Detailed Description
None
Recommended Response Action
Check presence, re-install or reconnect, then re-attempt the update. If the problem persists, contact support.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4014
Message
Link Tuning data successfully updated.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4015
Message
Link Tuning error detected.
Detailed Description
CMC has old firmware and does not recognize the new device which has requested link tuning information. After updating the
firmware the CMC will recognize the device.
Recommended Response Action
Update the CMC firmware. If the problem persists, contact support.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4016
Message
Hardware incompatibility detected with mezzanine card
arg1 .
Arguments
arg1 = number
Detailed Description
The system has detected a mezzanine card that is not supported on this system.
Recommended Response Action
1) Review system documentation for supported mezzanine cards. 2) Replace mezzanine card with a supported mezzanine card.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4017
Message
A hardware incompatibility is detected between
arg1arg2 and
arg3arg4 .
Arguments
arg1 = first component name
arg2 = first component location
arg3 = second component name
arg4 = second component location
Detailed Description
The system has detected an unsupported hardware component. A hardware incompatibility is detected between the components identifed
in the message.
Recommended Response Action
Do the following: 1) Review system documentation for the hardware components identified in the message. 2) Replace unsupported
components with supported components.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC4018
Message
A hardware incompatibility was corrected between
arg1arg2 and
arg3arg4 .
Arguments
arg1 = first component name
arg2 = first component location location
arg3 = second component name
arg4 = second component location
Detailed Description
A hardware incompatibility was corrected between the components identified in the message.
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5000
Message
arg1 is online.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5001
Message
arg1 is offline.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
If unexpected, check presence, then re-install or reconnect.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5002
Message
A fabric mismatch detected on
arg1 .
Arguments
arg1 = name
Detailed Description
The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the
fabric type is then set for the CMC and the CMC will ensure that all subsequent IOMs and mezzanine cards match.
Recommended Response Action
Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5003
Message
arg1 is operating correctly.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5004
Message
A link tuning failure detected on
arg1 .
Arguments
arg1 = name
Detailed Description
CMC has old firmware and does not recognize the new device which has requested link tuning information. After updating the
firmware the CMC will recognize the device.
Recommended Response Action
Update the CMC firmware. If the problem persists, contact support.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5006
Message
A failure is detected on
arg1 .
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5008
Message
Console is not available for the
arg1 .
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5010
Message
arg1 cannot detect any hosts.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5012
Message
On screen display (OSCAR) is not functional for the
arg1 .
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5014
Message
arg1 is not functional and is powered off.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5030
Message
IO module
arg1 is online.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5031
Message
IO module
arg1 is offline.
Arguments
arg1 = number
Detailed Description
The CMC has powered off the IOM.
Recommended Response Action
Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5032
Message
A fabric mismatch detected on IO module
arg1 .
Arguments
arg1 = number
Detailed Description
The fabric type for IOMs on the same chassis fabric must match.
Recommended Response Action
Check chassis fabric type in CMC GUI and compare to the type of both IOMs.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5033
Message
IO module
arg1 is operating correctly.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5034
Message
A link tuning failure detected on IO module
arg1 .
Arguments
arg1 = number
Detailed Description
Link tuning table not supported for this IO modular.
Recommended Response Action
Update the CMC firmware. If the problem persists, contact support.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5035
Message
An over-temperature event detected on I/O module
arg1 .
Arguments
arg1 = number
Detailed Description
The I/O module over heated.
Recommended Response Action
Do the following: 1) Make sure fans are installed and working correctly. 2) Check the temperature sensor status for the chassis
and make sure it is within the chassis operating temperature range. 3) Reseat the I/O module to clear the over-temperature
condition. If the problem persists, contact the service provider.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5036
Message
A failure is detected on IO module
arg1 .
Arguments
arg1 = number
Detailed Description
The IOM module performance may be impact.
Recommended Response Action
Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC5037
Message
I/O module
arg1 failed to boot.
Arguments
arg1 = number
Detailed Description
The firmware on the I/O module did not boot. The problem may be because the I/O module is not inserted correctly.
Recommended Response Action
Reseat I/O module. If problem persists, contact the service provider.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC6000
Message
The
arg1 controller is offline.
Arguments
arg1 = name
Detailed Description
Information and status from the controller is unavailable.
Recommended Response Action
Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose
a convenient contact method.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC6001
Message
The
arg1 controller is online.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC6002
Message
The
arg1 controller is stuck in boot mode.
Arguments
arg1 = name
Detailed Description
Information and status from the controller is unavailable.
Recommended Response Action
Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose
a convenient contact method.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC6003
Message
The
arg1 controller is booting.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC6004
Message
Cannot communicate with
arg1 controller.
Arguments
arg1 = name
Detailed Description
Information and status from the controller is unavailable.
Recommended Response Action
Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose
a convenient contact method.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC6005
Message
Communications restored for
arg1 controller.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC7000
Message
Server
arg1 health changed to a normal state.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC7002
Message
Server
arg1 health changed to a warning state from a normal state.
Arguments
arg1 = number
Detailed Description
Server health changed to a warning state from a normal state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC7004
Message
Server
arg1 health changed to a critical state from either a normal or warning state.
Arguments
arg1 = number
Detailed Description
Server <number> health changed to a critical state from either a normal or warning state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC7006
Message
Server
arg1 health changed to a non-recoverable state from a less severe state.
Arguments
arg1 = number
Detailed Description
Server <number> health changed to a non-recoverable state from a less severe state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC7008
Message
Server
arg1 health changed to a warning state from more severe state.
Arguments
arg1 = number
Detailed Description
Server <number> health changed to a warning state from more severe state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 2 (Warning)
Trap/EventID
2330
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC7010
Message
Server
arg1 health changed to a critical state from a non-recoverable state.
Arguments
arg1 = number
Detailed Description
Server <number> health changed to a critical state from a non-recoverable state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC7012
Message
Server
arg1 health changed to a non-recoverable state.
Arguments
arg1 = number
Detailed Description
Server <number> health changed to a non-recoverable state.
Recommended Response Action
Review System Log or front panel for additional information.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable
HWC8000
Message
Unknown device plug event occurred at this location:
arg1 . Additional Details:
arg2 .
Arguments
arg1 = device location
arg2 = details
Detailed Description
An unknown device plug event occurred at the identified device location. Along with the device location, additional event
details are provided if available.
Recommended Response Action
No response action is required.
Category
Audit
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5650
Server Administrator Trap ID
Not Applicable
HWC8001
Message
A device was added to the system at this location:
arg1 . Additional Details:
arg2 .
Arguments
arg1 = device location
arg2 = details
Detailed Description
A device was added to the system at the location identified in the message. Along with the device location, additional event
details are provided if available.
Recommended Response Action
No response action is required.
Category
Audit
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
SNMP Alert;OS Log;None
Server Administrator Event ID
5651
Server Administrator Trap ID
5651
HWC8002
Message
The device was removed from the system at this location:
arg1 . Additional Details:
arg2 .
Arguments
arg1 = device location
arg2 = details
Detailed Description
A device was was removed from the system at the location identified in the message. Along with the device location, additional
event details are provided if available.
Recommended Response Action
No response action is required.
Category
Audit
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
SNMP Alert;OS Log;None
Server Administrator Event ID
5652
Server Administrator Trap ID
5652
HWC8003
Message
A configuration error was detected in the device located here:
arg1 . Additional Details:
arg2 .
Arguments
arg1 = device location
arg2 = details
Detailed Description
A configuration error was detected for a pluggable device installed at the location identified in the message. The device
may not be installed correctly.
Recommended Response Action
Reinsert the device or try inserting a different device of the same type and retry the operation. If the issue persists, check
the system documentation to make sure the device is supported or contact your service provider.
The SD card device sensor of the type identified in the messaage has failed. The current status of the SD card is also displayed.
Recommended Response Action
Reinsert the SD card or try a different SD card and retry the operation. If the issue persists, do one of the following to
resolve the error: 1) If the SD card sensor is installed on the internal SD module, replace the module. 2) If the SD card
sensor is embedded on the system board, replace the system board. . For more information, contact your service provider.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5750
Server Administrator Trap ID
Not Applicable
HWC8005
Message
The SD card device has returned to normal state. SD card location:
arg1 , SD card device type:
arg2 , SD card state:
arg3 .
Arguments
arg1 = location
arg2 = type
arg3 = state
Detailed Description
The SD card device has returned to a normal state. The SD card type and the current status of the SD card is also displayed.
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5752
Server Administrator Trap ID
Not Applicable
HWC8006
Message
The SD card device state has changed to a warning state. SD card location:
arg1 , SD card device type:
arg2 , SD card state:
arg3 .
Arguments
arg1 = location
arg2 = type
arg3 = state
Detailed Description
The SD card device is not functioning correctly, and its state has changed to a warning state.
Recommended Response Action
Reinsert the SD card or try a different SD card and retry the operation. If the issue persists, do one of the following to
resolve the error: 1) If the SD card sensor is installed on the internal SD module, replace the module. 2) If the SD card
sensor is embedded on the system board, replace the system board. . For more information, contact your service provider.