Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.0

PDF

IOV Event Messages

IOV1007

Message
Unable to assign a PCIe slot.
Detailed Description
The IOV slot management subsystem detected an error which may prevent the physical assignment/unassignment or turning off of a PCIe slot. The errors can be caused by PCIe training timeouts, false hot plug signals,or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
Recommended Response Action
Insert only supported adaptor cards into system PCIe slots and make sure they are fully inserted. Retry the operation.
Category
Configuration
Subcategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

IOV1008

Message
Invalid Virtual Adapter FQDD arg1 .
Arguments
  • arg1 = FQDD value
Detailed Description
The FQDD (Fully Qualified Device Descriptor) value entered for the operation does not map to any DCIM_ChassisVAView class instance representing Virtual Adapters.
Recommended Response Action
Perform an Enumerate operation on the DCIM_ChassisVAView class to get the correct FQDD for the Virtual Adapter. Retry the operation with the correct FQDD value.
Category
Configuration
Subcategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

IOV1009

Message
Mismatch in Slot or Virtual Adapter FQDD and Server Slot FQDD count.
Detailed Description
The FQDD pairs identified in the messages do not match in the required method input parameters.
Recommended Response Action
Provide a valid pair of FQDDs. Please refer to the DCIM Chassis PCI Management Profile document for the required parameter definitions.
Category
Configuration
Subcategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
None
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\