Passer au contenu principal
  • Passer des commandes rapidement et facilement
  • Afficher les commandes et suivre l’état de votre expédition
  • Créez et accédez à une liste de vos produits
  • Gérer vos sites, vos produits et vos contacts au niveau des produits Dell EMC à l’aide de la rubrique Gestion des informations de l’entreprise.

Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Important Points to Remember

  • Port monitoring is supported on physical ports only; virtual local area network (VLAN) and port-channel interfaces do not support port monitoring.
  • The monitored (the source, [MD]) and monitoring ports (the destination, [MG]) must be on the same switch.
  • The monitored (source) interface must be a server-facing interface in the format slot/port, where the valid slot numbers are 0 and server-facing port numbers are from 1 to 8.
  • The destination interface must be an uplink port (ports 9 to 12).
  • In general, a monitoring port should have no ip address and no shutdown as the only configuration; the Dell Networking OS permits a limited set of commands for monitoring ports. You can display these commands using the ? command.
  • A monitoring port may not be a member of a VLAN.
  • There may only be one destination port in a monitoring session.
  • A source port (MD) can only be monitored by one destination port (MG). If you try to assign a monitored port to more than one monitoring port, the following message displays:
    Dell(conf)#mon ses 1
                                           Dell(conf-mon-sess-1)#source tengig 0/1 destination tengig 0/8 direction both
                                           Dell(conf-mon-sess-1)#do show monitor session
                                           
                                           SessionID   Source       Destination   Direction    Mode       Type
                                           ---------   ------       -----------   ---------    ----        ----
                                           1    TenGig 0/1    TenGig 0/8   both        interface   Port-based
                                           
                                           Dell(conf-mon-sess-1)#mon ses 2
                                           Dell(conf-mon-sess-2)#source tengig 0/1 destination tengig 0/8 direction both
                                           % Error: MD port is already being monitored.
                                        
  • NOTE: There is no limit to the number of monitoring sessions per system, provided that there are only four destination ports per port-pipe. If each monitoring session has a unique destination port, the maximum number of session is four per port-pipe.

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\