メイン コンテンツに進む
  • すばやく簡単にご注文が可能
  • 注文内容の表示、配送状況をトラック
  • 会員限定の特典や割引のご利用
  • 製品リストの作成とアクセスが可能
  • 「Company Administration(会社情報の管理)」では、お使いのDell EMCのサイトや製品、製品レベルでのコンタクト先に関する情報を管理できます。

OptiPlex 7050 Micro Owner's Manual

Power LED issue

Power LED is not flashing amber on ChengMing 3977 and Optiplex D8 and OptiPlex D8 AIO platforms.

ChengMing 3977 and OptiPlex D8 and D8 AIO platforms without processor installed or when processor power cable is not connected; it may not have the power LED flashing amber as the diagnostic indicator. The BIOS behavior specification defines that:
  1. If no processor is installed in the system, the power LED should flash amber in pattern of 2-3
  2. If no processor cable is connected in the system, the power LED should flash amber in pattern of 2-2

Do not replace any hardware, it works as per the design. With the Boot guard (BtG) feature of Intel ME11.6, when processor power or processor is missing, then the system will shut down.

Affected Platforms:

  • ChengMing 3977
  • OptiPlex 3050/5050/7050
  • OptiPlex 3050 AIO/5250 AIO/7450 AIO