Dell PowerEdge R330 Owner's Manual

Cooling fans

Depending on your system configuration, your system can support up to four cooling fans.

NOTE: Hot swappable removal or installation of the fans is not supported.

NOTE: Each fan is listed in the management software of the system, referenced by the respective fan number. If there is a problem with a particular fan, you can easily identify and replace the proper fan by noting down the fan numbers provided on the cooling fans.

The following table shows the number of fans required for different system configurations:

Table 1. Number of fans based on system configurationSystems with four 3.5-inch hot swappable or four 2.5-inch hard drives with adapter support three cooling fans. Systems with four 3.5-inch hard drives or four 2.5-inch hard drives with adapter with PCIe riser card support four cooling fans. Systems with eight 2.5-inch hard drives support four cooling fans.
System configuration Number of fans
Systems with four 3.5-inch hard drives or four 2.5-inch hard drives with adapter 3
Systems with four 3.5-inch hard drives or four 2.5-inch hard drives with adapter with PCIe riser card 4
Systems with eight 2.5-inch hard drives 4

NOTE: Ensure that you install a cooling fan blank in an empty cooling fan bracket.