Pular para o conteúdo principal
  • Faça pedidos de forma rápida e simples
  • Visualize os pedidos e acompanhe o status de envio
  • Crie e acesse uma lista dos seus produtos
  • Gerencie seus sites, produtos e contatos de nível de produto da Dell EMC usando o Company Administration.

Dell Chassis Management Controller Version 1.3 for PowerEdge FX2/FX2s RACADM Command Line Reference Guide

PDF

serveraction

Description

Enables you to perform power management operations on the host system.

To use this subcommand, you must have the Execute Server Control Commands permission.

Synopsis

racadm serveraction <
                                                action> 
                                             

Input

  • -m < module> -

    server-n, where n=1–4

  • -a - Performs action on all servers. Not allowed with the powerstatus action.
  • < action>- Specifies the action. The options for the < action> string are:

    — graceshutdown — Performs a graceful shutdown of the server. If the operating system on the server cannot be cleanly shutdown, this operation will not be performed.

    — hardreset — Performs a reset (reboot) operation on the managed system.

    — powercycle — Issues a power-cycle operation on the managed system. This action is similar to pressing the power button on the system’s front panel to turn off, and then turn on the system.

    — powerdown — Turns off the managed system.

    — powerup — Turns on the managed system.

    — powerstatus — Displays the current power status of the server (ON or OFF).

    — reseat — Performs a virtual reseat of the server. This operation simulates reseating the server by resettig the iDRAC on a server.

    • NOTE: The reseat option is not available for individual FM120 servers.
  • NOTE: The action powerstatus is not allowed with an -a option.

Output

Displays an error message if the requested operation fails, or a success message if the operation is completed.

Example

  • Turn off server 3 from the CMC
    racadm serveraction -m server-3 powerdown

    Server power operation successful

  • Turn off server 3 from iDRAC
    racadm serveraction powerdown

    Server power operation successful

  • Turn off server 3 from CMC when Power is already turned off on that server
    racadm serveraction -m server-3 powerdown

    Server is already powered OFF.

  • Turn off the server from CMC when Power is already turned off on that server.
    racadm serveraction powerdown

    Server is already powered OFF

  • Get Power Status of server 2 on CMC
    racadm serveraction -m server-2 powerstatus

    ON

  • Get Power status action on multinode server:
    racadm serveraction -m server-1a powerstatus
  • Get Power Status on iDRAC
    racadm serveraction powerstatus

    Server Power Status: ON

  • Reseat action on a multinode sled
    racadm serveraction -f -m sled-1 reseat
  • Explanation of Support

    CMC needs to support graceful shutdown

    The support of address individual blades is expected on the CMC


Classifique este conteúdo

Preciso
Úteis
Fácil de entender
Este artigo foi útil?
0/3000 characters
  Forneça as classificações (de 1 a 5 estrelas).
  Forneça as classificações (de 1 a 5 estrelas).
  Forneça as classificações (de 1 a 5 estrelas).
  Selecione se o artigo foi útil ou não.
  Os comentários não podem conter estes caracteres especiais: <>()\