All possible Platform Event Filter (PEF) Alert Messages along with a description of each event are listed in the table below

Table 1. BMC PEF Alert Events
Event Description
Fan Probe Failure

The fan is running too slow or not at all.

Voltage Probe Failure

The voltage is too low for proper operation.

Discrete Voltage Probe Failure

The voltage is too low for proper operation.

Temperature Probe Warning

The temperature is approaching excessively high or low limits.

Temperature Probe Failure

The temperature is either too high or too low for proper operation.

Chassis Intrusion Detected

The system chassis has been opened.

Redundancy (PS or Fan) Degraded

Redundancy for the fans and/or power supplies has been reduced.

Redundancy (PS or Fan) Lost

No redundancy remains for the system's fans and/or power supplies.

Processor Warning

A processor is running at less than peak performance or speed.

Processor Failure

A processor has failed.

PPS/VRM/DCtoDC Warning

The power supply, voltage regulator module, or DC-to-DC converter is pending a failure condition.

Power Supply/VRM/D2D Failure

The power supply, voltage regulator module, or DC-to-DC converter has failed.

Hardware log is full or emptied

Either an empty or a full hardware log requires administrator attention.

Automatic System Recovery

The system is hung or is not responding and is taking an action configured by Automatic System Recovery.

System Power Probe Warning

The system is setting actions when a power consumption probe detects a warning value.

System Power Probe Failure

The system is setting actions when a power consumption probe detects a failure value.