<Power Supply Sensor Name> power supply sensor removed.
|
Critical |
This event is generated when the power supply sensor is removed. |
<Power Supply Sensor Name> power supply sensor AC
recovered.
|
Information |
This event is generated when the power supply has been replaced. |
<Power Supply Sensor Name> power supply sensor returned
to normal state.
|
Information |
This event is generated when the power supply that failed or
removed was replaced and the state has returned to normal.
|
<Entity Name> PS Redundancy sensor redundancy degraded.
|
Information |
Power supply redundancy is degraded if one of the power supply
sources is removed or failed.
|
<Entity Name> PS Redundancy sensor redundancy lost.
|
Critical |
Power supply redundancy is lost if only one power supply is
functional.
|
<Entity Name> PS Redundancy sensor redundancy regained.
|
Information |
This event is generated if the power supply has been reconnected
or replaced.
|
<Power Supply Sensor Name> predictive failure was
asserted.
|
Critical |
This event is generated when the power supply is about to fail. |
<Power Supply Sensor Name> input lost was asserted.
|
Critical |
This event is generated when the power supply is unplugged. |
<Power Supply Sensor Name> predictive failure was
deasserted.
|
Information |
This event is generated when the power supply has recovered
from an earlier predictive failure event.
|
<Power Supply Sensor Name> input lost was deasserted.
|
Information |
This event is generated when the power supply is plugged in. |
PS 1 Status: Power supply sensor for PS 1, presence
was asserted.
|
Information |
This event is generated when the power supply is plugged in. |
PS 1 Status: Power supply sensor for PS 1, presence
was deasserted.
|
Critical |
This event is generated when the power supply is removed. |
PS 1 Status: Power supply sensor for PS 1, failure
was asserted.
|
Critical |
This event is generated when the power supply has failed. |
PS 1 Status: Power supply sensor for PS 1, failure
was deasserted.
|
Information |
This event is generated when the power supply has recovered
from an earlier failure event.
|
PS 1 Status: Power supply sensor for PS 1, predictive
failure was asserted.
|
Warning |
This event is generated when the power supply is about to fail. |
PS 1 Status: Power supply sensor for PS 1, predictive
failure was deasserted.
|
Information |
This event is generated when the power supply has recovered
from an earlier predictive failure event.
|
PS 1 Status: Power supply sensor for PS 1, input lost
was asserted.
|
Critical |
This event is generated when AC power is removed from the power
supply.
|
PS 1 Status: Power supply sensor for PS 1, input lost
was deasserted.
|
Information |
This event is generated when the power supply is plugged in. |
PS 1 Status: Power supply sensor for PS 1, configuration
error was asserted.
|
Warning/Critical |
This event is generated when an invalid power supply configuration
is detected.
|
PS 1 Status: Power supply sensor for PS 1, configuration
error was deasserted.
|
Information |
This event is generated when the power supply has recovered
from an earlier invalid configuration.
|
Power supply <number> is present.
|
Information |
This event is generated when the power supply is plugged in. |
Power supply <number> is absent.
|
Critical |
This event is generated when the power supply is removed. |
Power supply <number> failed.
|
Critical |
This event is generated when the power supply has failed. |
A predictive failure detected on power supply <number>.
|
Warning |
This event is generated when the power supply is about to fail. |
The power input for power supply <number> is lost.
|
Critical |
This event is generated when input power is removed from the
power supply.
|
The input power for power supply <number> has been
restored.
|
Information |
This event is generated if the power supply has been reconnected
or replaced.
|
Power supply <number> is incorrectly configured.
|
Critical/Warning |
This event is generated when an invalid power supply configuration
is detected.
|
Power supply <number> is correctly configured.
|
Information |
This event is generated when the power supply has recovered
from an earlier invalid configuration.
|
Power supply <number> is operating normally.
|
Information |
This event is generated when the power supply has recovered
from an earlier failure event.
|
Cannot communicate with power supply <number>.
|
Critical |
The power supply may operate, however power supply monitoring
is degraded.
|
The temperature for power supply <number> is in
a warning range.
|
Warning |
Temperature of specified power supply entered into non-critical
state.
|
The temperature for power supply <number> is outside
of range.
|
Critical |
Temperature of specified power supply entered into critical
state.
|
An under voltage fault detected on power supply <number>.
|
Critical |
The specified power supply detected inefficient voltage. |
An over voltage fault detected on power supply <number>.
|
Critical |
The specified power supply detected an over voltage condition. |
An over current fault detected on power supply <number>.
|
Crotoca; |
The specified power supply detected an over current condition. |
Fan failure detected on power supply <number>.
|
Critical |
The specified power supply fan has failed. |
Communication has been restored to power supply <number>.
|
Information |
This event is generated when the power supply has recovered
from an earlier communication problem.
|
A power supply wattage mismatch is detected; power
supply <number> is rated for <value> watts.
|
Critical |
This event is generated when there is more than one power supplies
in the system and the power supply wattage do not match.
|
Power supply <number> wattage mismatch corrected.
|
Information |
This event is generated when the power supply has recovered
from an earlier power supply wattage mismatch.
|
Power supply redundancy is lost.
|
Critical |
Power supply redundancy is lost if only one power supply is
functional.
|
Power supply redundancy is degraded.
|
Warning |
Power supply redundancy is degraded if one of the power supply
sources is removed or failed.
|
The power supplies are redundant.
|
Information |
This event is generated if the power supply has been reconnected