SCv3000 and SCv3020 Storage System Deployment Guide

Create Test Volumes

Connect a server to the Storage Center, create one or more test volumes, and map them to the server to prepare for connectivity and failover testing.

Prerequisites

NOTE: The localhost must have network connection to both the iSCSI connection and Data Collector host IP.

Steps

  1. Configure a localhost to access the Storage Center using the Set up localhost on wizard.
    1. In the Storage view, select a Storage Center.
    2. Click the Storage tab, then click Servers > Create Server from Localhost.
  2. Connect to the Storage Center using the Dell Storage Manager.
  3. Create two small test volumes (TestVol1 and TestVol2) on the server.
  4. Map TestVol1 to storage controller 1 and TestVol2 to storage controller 2.
  5. Partition and format the test volumes on the server.