Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

SCv3000 and SCv3020 Storage System Deployment Guide

SCv3000 and SCv3020Storage System and Two SCv360Expansion Enclosures

This figure shows anSCv3000 and SCv3020 storage system cabled to two SCv360expansion enclosures.

Figure 1. SCv3000 and SCv3020 and Two SCv360Expansion Enclosures
SCv3000 and SCv3020 connected to two SCv360 expansion enclosures
  1. Storage system
  2. Storage controller 1
  3. Storage controller 2
  4. Expansion enclosure 1
  5. Expansion enclosure 2
The following table describes the back-end SAS connections from anSCv3000 and SCv3020 storage system to two SCv360expansion enclosures.
Table 1. SCv3000 and SCv3020 and Two SCv360Expansion EnclosuresBack-end connections to two SCv360expansion enclosures
PathConnections
Chain 1: Side A (orange)
  1. Storage controller 1: port 1 to expansion enclosure 1: left EMM, port 1
  2. Expansion enclosure 1: left EMM, port 3 to expansion enclosure 2: left EMM, port 1
  3. Expansion enclosure 2: left EMM, port 3 to storage controller 2: port 2
Chain 1: Side B (blue)
  1. Storage controller 2: port 1 to expansion enclosure 1: right EMM, port 1
  2. Expansion enclosure 1: right EMM, port 3 to expansion enclosure 2: right EMM, port 1
  3. Expansion enclosure 2: right EMM, port 3 to storage controller 1: port 2