System Event =
Type 1
|
System requires a Restore Manager (RM) recovery. |
|
System failed basic initialization. |
|
HTTP Service failed. Web services will be unavailable. |
|
HTTP Service started. |
Informational message. No user intervention is
required.
|
HTTP Service is available now. |
Informational message. No user intervention is
required.
|
Diagnostics collection service failed. |
|
Diagnostic collection service started. |
Informational message. No user intervention is
required.
|
Diagnostics collection service re-started. |
Informational message. No user intervention is
required.
|
Configuration Service started. |
Informational message. No user intervention is
required.
|
Configuration Service is not healthy. |
|
Configuration Service is healthy. |
Informational message. No user intervention is
required.
|
Configuration Service failed to start. |
|
Unsupported RAID Configuration detected. |
|
No Fault Tolerant RAID configuration found. |
|
Data volume not present. |
Check all drives are inserted and powered up. |
Unable to detect filesystem type on data volume. |
|
Non certified disk drive detected. Disk needs
to be pulled out for the system to become operational.
|
Disk needs to be pulled out for the system to
become operational.
|
NVRAM devices not found. |
Check card is seated properly. |
Invalid/Unsupported Network Configuration detected. |
Use CLI "network --restart" to re-configure network
cards.
|
Some of the network cards are not part of the bond
configuration.
|
|
No IP address has been assigned to the system. |
|
No valid hostname has been assigned to the system. |
Use "system --setname" to set hostname. |
No valid system name found in configuration Database. |
Use "maintenance --configuration --restore" to
recover from backup configuration.
|
No valid system configuration file(s) found in
configuration database.
|
Use "maintenance --configuration --restore" to
restore from backup configuration.
|
Data volume filesystem is not yet initialized. |
|
Backup configuration file is missing. |
Contact Dell Support. |
Working configuration file is missing. |
Use "maintenance --configuration --restore" to
restore configuration from backup.
|
Working configuration file is corrupted. |
Use "maintenance --configuration --restore" to
restore configuration from backup.
|
NVRAM signature is missing. |
If NVRAM device was replaced use "maintenance
--hardware --reinit_nvram" to initialize NVRAM.
|
Windows Active Directory client module failed to
start. Active Directory support will not be available.
|
|
Windows Active Directory client module started. |
Informational message. No user intervention is
required.
|
Windows Server module started. |
Informational message. No user intervention is
required.
|
Windows Server module re-started. |
Informational message. No user intervention is
required.
|
Windows Server module is down. Windows client
access will be disrupted.
|
|
Windows Server module has been disabled because
of multiple crashes.
|
|
System initialization is required. |
Informational message. No user intervention is
required.
|
Filesystem server maintenance requested. |
|
Filesystem server re-started. |
Informational message. No user intervention is
required.
|
Filesystem server started. |
Informational message. No user intervention is
required.
|
Filesystem server re-started, in Read-Only mode. |
Informational message. No user intervention is
required.
|
Filesystem server started, in Read-Only mode. |
Informational message. No user intervention is
required.
|
Filesystem server is not healthy. Client access
will be interrupted.
|
|
Filesystem scan triggered. |
|
Filesystem check re-started. |
Informational message. No user intervention is
required.
|
Filesystem check continued from previous boot. |
Informational message. No user intervention is
required.
|
Filesystem checker is not healthy, will be re-started. |
|
Filesystem checker terminated with unexpected
error.
|
|
Filesystem checker crashing multiple times, entering
support mode.
|
Please contact Dell Support. |
Diagnostics collection module failed to start. |
Reboot the system to recover. If problem persists
contact Dell Support.
|
Hardware Health Monitor module failed to start. |
Reboot the system to recover. If problem persists
contact Dell Support.
|
System is exiting Support Mode. |
Informational message. No user intervention is
required.
|
De-dupe engine dictionary is corrupted. |
Use "maintenance --configuration --reinit_dictionary"
to re-init.
|
Not enough memory to validate NVRAM contents. |
System reboot is required. |
Failed to complete basic system initialization. |
|
Unable to detect filesystem type on the Name Space
Volume.
|
|
Name Space Volume is not mounted. |
|
iSCSI server started. |
Informational message. No user intervention is
required.
|
iSCSI server re-started. |
Informational message. No user intervention is
required.
|
iSCSI server is not healthy. |
|
iSCSI server is crashing repeatedly. |
Contact Dell Support. |
NDMP tape server started. |
Informational message. No user intervention is
required.
|
NDMP tape server re-started. |
Informational message. No user intervention is
required.
|
NDMP tape server is not healthy. |
|
NDMP tape server has crashed repeatedly. |
Contact Dell Support. |
Virtual Tape Library daemons started successfully. |
Informational message. No user intervention is
required.
|
Virtual Tape Library daemons re-started successfully. |
Informational message. No user intervention is
required.
|
Virtual Tape Library daemons are not healthy. |
|
Virtual Tape Library daemons have crashed repeatedly.
All Virtual Tape functionality will not be available.
|
|
Failed to process deleted files and containers. |
Contact Dell Support. |
Internal failure processing ingest log. |
Contact Dell Support for assistance or intervention. |
Hardware Health Monitor Database is corrupted. |
Use "maintenance --hardware --restore_hw_db". |
Unable to communicate with Hardware Health Monitor. |
Informational message. No user intervention is
required.
|
Unable to communicate with NVRAM device. Check
hardware.
|
Verify that the NVRAM card is seated properly in
the DR Series system appliance. Contact Dell Support for assistance
or intervention.
|
Capacitor is disconnected from NVRAM. If problem
persist after reboot, replace NVRAM card.
|
Contact Dell Support for assistance or intervention. |
SSD is disconnected from NVRAM device. If problem
persist after reboot, replace NVRAM card.
|
Contact Dell Support for assistance or intervention. |
NVRAM capacitor is not charging. If problem persist
after 5 minutes of power shutdown, replace NVRAM card.
|
Contact Dell Support for assistance or intervention. |
NVRAM has failed to backup or restore data during
the last boot.
|
Contact Dell Support for assistance or intervention. |
NVRAM is not yet ready to accept write commands. |
Wait for NVRAM to become ready. |
NVRAM hardware has failed. |
Contact Dell Support for assistance or intervention. |
Filesystem server is crashing repeatedly. Entering
Maintenance mode to run filesystem scan utility.
|
|
System is not initialized. |
Use "system --init" to initialize the system. |
NVRAM does not match the data volume. |
If this is a newly replaced NVRAM, use "maintenance
--hardware --reinit_nvram" to initialize.
|
Software upgrade is in progress. |
Informational message. No user intervention is
required.
|
Upgrade did not complete. |
Retry upgrade after rebooting the appliance. |
Upgrade completed successfully. Reboot required. |
Reboot the system. |
Upgrade completed successfully. System coming online. |
Informational message. No user intervention is
required.
|
Unable to set Filesystem Scan Markers. |
Reboot the system. If problem persist contact
Dell Support.
|
Not enough space to run Filesystem Scan. |
Please clean-up older diagnostics file(s) and
reboot the system. On reboot, execute "maintenance --filesystem --start_scan"
to start filesystem scan. If the file system scan fails with not enough
space, please contact Dell Support.
|
Filesystem server is crashing repeatedly in Maintenance
Mode.
|
Please contact Dell Support. |
One or more software package is incompatible,
please upgrade the appliance to rectify the issue.
|
Please upgrade the system appliance to rectify
the issue. Upgrade the DR Series system appliance (in the
Software Upgrade page, click
Start Upgrade).
|
NVRAM Controller detected a memory failure |
|
NVRAM Health check in progress, please wait for
it to complete before using the system.
|
Informational message. No user intervention is
required.
|
NVRAM Health check is required, system will perform
a quick health check
|
Informational message. No user intervention is
required.
|
Failed to start NVRAM Health check, please reboot
the appliance to recover from this state
|
Reboot the system. |
Appliance encountered O/S issues. Please reboot
the appliance to recover from this condition.
|
Reboot the system. |
High system memory usage detected, system performance
will be sluggish.
|
|
System memory usage has returned to an optimal
level.
|
Informational message. No user intervention is
required.
|
A high level of system process usage has been detected,
if it persists, please collect system diagnostics.
|
Informational message. No user intervention is
required.
|
System process usage has returned to an optimal
level.
|
Informational message. No user intervention is
required.
|
A high-temperature reading has been detected on
the NVRAM PCI controller. System will operate only in a read-only
mode. Please check system airflow.
|
Informational message. No user intervention is
required.
|
A high-temperature reading has been detected on
the NVRAM PCI controller. System will not become operational until
the temperature reduces to an ambient value of 55 degrees Celsius
(131 degrees Fahrenheit).
|
Informational message. No user intervention is
required. If issue persists, contact Dell Support for assistance or
intervention.
|
The next NVRAM capacitor health check is scheduled
for <
variable>.
|
Informational message. No user intervention is
required.
|
Windows Active Directory client is unable to contact
the Active Directory domain server.
|
Informational message. No user intervention is
required.
|
Active Directory domain server connectivity is
restored.
|
Informational message. No user intervention is
required.
|
Storage enclosure <
variable> is authorized.
|
Informational message. No user intervention is
required.
|
Storage enclosure <
variable> is de-commissioned.
|
Informational message. No user intervention is required. |
The system IP address has changed from <
variable> to <
variable>.
|
Informational message. No user intervention is
required.
|
Refresh NHM Inventory |
|
One or more storage enclosures have gone offline,
please power-off the appliance, fix the connectivity issues and power-on
the appliance.
|
Please power off the appliance, check whether
all required storage enclosure(s) are powered-up, fix connectivity
issues, and power on the appliance.
|
Data Volume has become in-accessible. |
Contact Dell Support. |
Data Volume has become read-only. |
Contact Dell Support. |
Namespace Volume has become in-accessible, please
call Dell support.
|
Contact Dell Support. |
Namespace Volume has become read-only. |
Contact Dell Support. |
Core Volume has become in-accessible. |
Contact Dell Support. |
Invalid storage appliance memory configuration. |
|
Storage Enclosure with Service Tag <
variable> added successfully.
|
Informational message. No user intervention is
required.
|
One of the storage enclosure has become offline. |
Power-off the appliance, fix the connectivity
issues and power-on the appliance.
|
Data Volume has become read-only. |
Contact Dell Support. |
Upgrade did not complete. Retry upgrade. |
Retry to upgrade. If the problem persists, contact
Dell Support.
|
Filesystem scan completed, restarting filesystem
for normal operation.
|
Informational message. No user intervention is
required.
|
Storage enclosure license(s) are missing. |
If Restore Manager (RM) recovery was performed
recently, please re-apply the license(s) and reboot.
|
BIOS System ID is incorrect for correct operation
of this storage appliance. The storage appliance requires service.
|
|
System clock has drifted more than 24 hours, from
the last filesystem start.
|
Please check your clock settings and reboot. |
This DR4x00 Virtual Machine usage time limit has
expired.
|
Please contact your DR4x00 Sales representative
to get the Hardware Version.
|
This DR4x00 Virtual Machine is for evaluation
purpose only. Evaluation period ends on <
variable>.
|
Informational message. No user intervention is
required.
|
This DR4x00 Virtual Machine requires an evaluation
license.
|
Please contact your DR4x00 Sales representative. |
This DR4x00 Virtual Machine is designed to work
only with 4 CPU(s) and 8GB of memory.
|
Informational message. No user intervention is
required.
|
This DR2000v requires a license to operate. |
Please install an evaluation license or register
the DR2000v with a DR4000/DR4100/DR6000 series hardware appliance.
|
This DR2000v is unable to contact the license server
to validate the license usage.
|
Please rectify the connectivity issues and reboot
the system.
|
This DR2000v Virtual appliance usage time limit
has expired.
|
Contact your Dell DR Series Sales representative
to get a permanent license.
|
This DR2000v Virtual appliance usage time limit
will expire on <
variable>.
|
Informational message. No user intervention is
required.
|
System Asset Tag information has non-printable
characters.
|
Please use the iDRAC interface console and fix
the issue.
|
This DR2000v has been deleted at license server. |
Register using the CLI command "virtual_machine
--register" again.
|
This DR4300e requires a license to operate, please
install storage usage license.
|
You need to install a capacity license. Contact
Dell Support for assistance.
|
Internal storage license(s) are missing, if Restore
Manager (RM) recovery was performed recently, please re-apply the
license(s).
|
Re-add the old capacity license(s) after recovering
the system. Contact Dell Support for assistance.
|
DR4300e data storage expanded successfully. |
Informational message. Storage on DR4300e has now
been expanded to 9TB after the addition of a second 4.5TB license.
No user intervention is required.
|
Filesystem scan requested. Switching to Maintenance
Mode. Filesystem has read-only access.
|
Informational message. No user intervention is
required.
|
NVRAM not detected. |
Ensure card is seated properly. |
NVRAM capacitor is disconnected. |
Contact Dell Support. |
NVRAM capacitor has degraded. |
Contact Dell Support. |
NVRAM SSD is disconnected. |
Contact Dell Support. |
NVRAM has failed to backup/restore data during
last boot.
|
Contact Dell Support. |
NVRAM hardware failure. |
Contact Dell Support. |
Data volume is not present. Check that all drives
are inserted and powered up.
|
Contact Dell Support for assistance or intervention. |
Filesystem server failed to start after multiple
attempts.
|
Contact Dell Support for assistance or intervention. |
Filesystem server crashed multiple times. System
is now entering Maintenance mode.
|
Contact Dell Support for assistance or intervention. |
Insufficient disk space. Filesystem switched to
read-only mode.
|
Informational message. No user intervention is
required. If issue persists, contact Dell Support for assistance or
intervention.
|
Unable to detect filesystem type on the Data Volume. |
Contact Dell Support for assistance or intervention. |
Unable to detect filesystem type on the Namespace
Volume.
|
Contact Dell Support for assistance or intervention. |
Filesystem scan discovered inconsistencies. |
Please check report and take the recommended action.
Contact Dell Support for assistance or intervention.
|
NVRAM does not match data volume. |
If this is a newly replaced NVRAM device, use the
CLI
maintenance --hardware --reinit_nvram command. For more
information, see the
Dell DR Series System Command Line Reference
Guide
.
|
Storage usage is approaching the DR Series system
capacity.
|
Informational message. No user intervention is
required. If issue persists, contact Dell Support for assistance or
intervention.
|
Replication re-sync cannot proceed because the
Namespace depth has reached its maximum.
|
Informational message. No user intervention is
required. If issue persists, contact Dell Support for assistance or
intervention.
|
Filesystem has reached the maximum allowable file(s)
and directories limit. New file and directory creation will be denied
until sufficient space exists.
|
Please clean up the filesystem. If issue persists,
contact Dell Support for assistance or intervention.
|
Filesystem is reaching the maximum allowable file(s)
and directories limit. New file and directory creation will be denied
after the limit has been reached.
|
Please clean up the filesystem. If issue persists,
contact Dell Support for assistance or intervention.
|
Replication has encountered an unexpected error. |
Contact Dell Support for assistance or intervention. |
DataCheck has detected a potential corruption. |
Run data consistency checks at the first available
opportunity. If this issue persists, contact Dell Support for assistance
or intervention.
|
Datacheck detected potential namespace inconsistency. |
Run filesystem scan as soon as possible. ("maintenance
--filesystem --start_scan")
|
Datacheck detected inconsistency in lsu image. |
Run filesystem scan as soon as possible. ("maintenance
--filesystem --start_scan verify_rda_metadata")
|
Datacheck detected potential corrupt lsu info. |
Run filesystem scan as soon as possible. ("maintenance
--filesystem --start_scan verify_rda_metadata")
|
Temperature warning detected on NVRAM PCI controller. |
Please check the data center air conditioning,
rack ventilation, and internal cooling fans for any issues. Ensure
that there is proper air flow through the system appliance, and clean
the system cooling vents as needed. If issue persists, contact Dell
Support for assistance or intervention.
|
Filesystem Name Space partition has reached its
maximum allowable limit.
|
Please delete any old, unused file(s) or disable
replication(s). If issue persists, contact Dell Support for assistance
or intervention.
|
Filesystem Name Space partition is reaching its
maximum allowable limit.
|
New replication resynch(s) will be stopped. If
issue persists, contact Dell Support for assistance or intervention.
|
One or more software package is incompatible. |
Please upgrade the appliance to rectify the issue. |
Filesystem volume has become in-active. |
Please contact Dell Support for assistance or
intervention.
|
Filesystem server response time exceeded max threshold. |
Informational message. No user intervention is
required.
|
The memory capacity of the storage appliance is
below the minimum required for correct operation. The storage appliance
requires service.
|
|
An OST container quota is exceeded. |
Check the event for container details. |
One of the storage enclosure has become offline. |
Please power-down the appliance and rectify the
issue.
|
One or more storage enclosure(s) are missing/offline. |
Please check whether the storage enclosure(s)
are powered-up and connected to the appliance.
|
Storage enclosure license(s) are missing. |
If Restore Manager (RM) recovery was performed
recently, please re-apply the license(s) and reboot.
|
System has a huge backlog of book keeping work.
Filesystem cleaner will be enabled outside of schedule setting and
performance impact will be observed.
|
Informational message. No user intervention is
required.
|
System clock has drifted more than 24 hours, from
the last filesystem start.
|
Please check your clock settings and reboot. |
Replication is disconnected on one or more containers. |
Please check event log or replication stats for
details.
|
One or more replication target systems are running
low in space.
|
Please check event log or replication stats for
details.
|
Filesystem scan completed with no inconsistencies.
Switching back to operational mode.
|
Informational message. No user intervention is
required.
|
Replication detected potential inconsistency. |
Run filesystem scan with data verification check
as soon as possible. ("maintenance --filesystem --start_scan verify_data")
|
Seeding device became full. |
Add new seeding device to continue. |
Seeding cannot contact the target device. |
Check to make sure that the target device is available
and write-enabled. Then remove and re-add the target device.
|
Seeding process complete. |
Informational message. No user intervention is
required.
|
System has reached space full condition, seeding
will be stopped.
|
Informational message. No user intervention is
required.
|
Seeding failed to create Zero log entries. |
Switch to maintenance mode to correct the issue. |
Found corrupted stream on seeding device. This
error will be rectified during replication re-sync done on this seed
data.
|
Informational message. No user intervention is
required.
|
Seeding device metadata info file missing, unable
to import.
|
|
Seeding device mount not accessible. |
|
Seeding export paused as the device contains data
from another seeding job.
|
Cleanup the device and re-add to continue seeding. |
Seeding encountered error. |
|
Unable to decrypt the Seeding data. |
Please check that the "password" and "encryption
type" matches the Seeding export job.
|
System diagnostics partition is running low on
space.
|
Please copy out the old diagnostics bundles and
delete for future auto diagnostics collection.
|
Appliance available storage level is below the
set threshold.
|
Please schedule filesystem cleaner or expire older
backups.
|
Primary Keystore corruption detected. |
Run filesystem scan with data verification check. |
System Event =
Type 2
|
Data check configuration successful. |
Informational message. No user intervention is
required.
|
Successfully <
variable> system marker.
|
Informational message. No user intervention is
required.
|
<
variable> OPDUP encryption updated to
<
variable>
|
Informational message. No user intervention is
required.
|
System storage usage alert has been set at <
level>.
|
Informational message. No user intervention is
required.
|
Successfully <
variable> container <
variable> with the following marker(s) "<
markers>".
|
Informational message. No user intervention is
required.
|
Container <
name> created successfully.
|
Informational message. No user intervention is
required.
|
Container <
name> marked for deletion.
|
For more information, see
Deleting Containers. Use the DR Series system CLI
maintenance --filesystem --reclaim_space command to recover this storage space.
|
Container <
name> has been deleted.
|
Informational message. No user intervention is
required.
|
Successfully renamed container <
name>
as <
name>.
|
Informational message. No user intervention is
required.
|
Container <
name> is configured to access
over <
variable> by the following clients: <
clients> ('*' means access for everyone).
|
Informational message. No user intervention is
required.
|
Container <
name> is updated to access
over <
variable> by the following clients: <
clients> ('*' means access for everyone).
|
Informational message. No user intervention is
required.
|
Disabled access for Container <
name> over <
variable> for the following clients: <
clients> ('*' means disabled access for everyone).
|
Informational message. No user intervention is
required.
|
Successfully added connection entry for container
<
name>: type <
variable> clients <
variable>.
|
Informational message. No user intervention is
required.
|
Successfully updated connection entry for container
<
name>: type <
variable> clients <
variable>.
|
Informational message. No user intervention is
required.
|
Successfully deleted connection entry for container
<
name>: type <
variable> clients <
variable>.
|
Informational message. No user intervention is
required.
|
Replication entry created successfully for container
<
name>: role <
variable> peer <
variable> peer container <
variable>.
|
Informational message. No user intervention is
required.
|
Replication configuration updated successfully
for container <
name>: role <
variable> peer <
variable>.
|
Informational message. No user intervention is
required.
|
Replication marked for deletion for Container <
name>: peer <
variable> peer container <
name>.
|
Informational message. No user intervention is
required.
|
Replication deleted for container <
name>.
|
Informational message. No user intervention is
required.
|
Successfully initiated replication re-sync on
Container <
name>.
|
Informational message. No user intervention is
required.
|
Replication <
variable> defaults successfully
updated: role <
variable> peer <
variable>.
|
Informational message. No user intervention is
required.
|
Successfully updated replication bandwidth limit
for <
variable> to <
variable>.
|
Informational message. No user intervention is
required.
|
Successfully removed replication bandwidth limit
for <
variable>.
|
Informational message. No user intervention is
required.
|
Successfully set <
variable> replication
bandwidth limit.
|
Informational message. No user intervention is
required.
|
Replication enabled for container <
name> with role <
role>.
|
Informational message. No user intervention is
required.
|
Replication disabled for container <
name> with role <
role>.
|
Informational message. No user intervention is
required.
|
Snapshot <
variable> → <
variable> created successfully.
|
Informational message. No user intervention is
required.
|
Snapshot <
variable> → <
variable> successfully updated.
|
Informational message. No user intervention is
required.
|
Snapshot <
variable> → <
variable> successfully deleted.
|
Informational message. No user intervention is
required.
|
Client <
client> authorized to access
NDMP Tape Server.
|
Informational message. No user intervention is
required.
|
Successfully updated NDMP to use port <
number>.
|
Informational message. No user intervention is
required.
|
De-authorized NDMP client - <
client>.
|
Informational message. No user intervention is
required.
|
NDMP password successfully updated. |
Informational message. No user intervention is
required.
|
OST password updated successfully. |
Informational message. No user intervention is
required.
|
OST state updated successfully. |
Informational message. No user intervention is
required.
|
OST client <
variable> with mode <
variable> added successfully
|
Informational message. No user intervention is
required.
|
OST client <
variable> deleted successfully.
|
Informational message. No user intervention is
required.
|
OST client <
variable> with mode <
variable> updated successfully.
|
Informational message. No user intervention is
required.
|
OST client <
variable> deleted successfully.
|
Informational message. No user intervention is
required.
|
OST client <
variable> with mode <
variable> updated successfully.
|
Informational message. No user intervention is
required.
|
Successfully updated <
variable> schedule.
|
Informational message. No user intervention is
required.
|
System compression level set to <
variable>.
|
Informational message. No user intervention is
required.
|
System configuration backup failed. |
|
Rapid Data Access (RDA) password updated successfully. |
Informational message. No user intervention is
required.
|
Rapid Data Access (RDA) state updated successfully. |
Informational message. No user intervention is
required.
|
Rapid Data Access (RDA) client <
variable> with mode <
variable> added successfully.
|
Informational message. No user intervention is
required.
|
Rapid Data Access (RDA) client <
variable> deleted successfully.
|
Informational message. No user intervention is
required.
|
Rapid Data Access (RDA) client <
variable> with mode <
variable> updated successfully.
|
Informational message. No user intervention is
required.
|
DR2000v with UUID <
variable> IP Address
<
variable> Hostname <
variable> registered successfully.
|
Informational message. No user intervention is
required.
|
DR2000v with UUID <
variable> IP Address
<
variable> Hostname <
variable> unregistered successfully.
|
Informational message. No user intervention is
required.
|
System Event =
Type 3
|
System is entering Maintenance mode. |
Informational message. No user intervention is
required. Contact Dell Support for assistance or intervention.
|
System entering Support Mode. |
Contact Dell Support for assistance or intervention. |
Internal failure—OFS client initialization failure. |
Contact Dell Support for assistance or intervention. |
Internal failure—mtab initialization failure for
container <
variable>.
|
Contact Dell Support for assistance or intervention. |
Internal failure—cannot initialize node mtab. |
Contact Dell Support for assistance or intervention. |
Internal failure retrieving configuration for
container ID <
variable>.
|
Contact Dell Support for assistance or intervention. |
Internal failure deleting container ID <
variable>.
|
Contact Dell Support for assistance or intervention. |
Internal failure stopping container ID <
variable>.
|
Contact Dell Support for assistance or intervention. |
Internal failure adding connection <
variable> for container ID <
variable>.
|
Contact Dell Support for assistance or intervention. |
Internal failure deleting connection <
variable> for container ID <
variable>.
|
Contact Dell Support for assistance or intervention. |
Name space volume nearing low space condition.
To prevent faster exhaustion of space, snapshot required for replication
seeding for container <
variable> will be paused until Name
space volume recovers from low space conditions.
|
|
Replication started as per schedule, will be active
until <
variable>.
|
Informational message. No user intervention is
required.
|
Replication stopped as per schedule, will restart
at <
variable>.
|
Informational message. No user intervention is
required.
|
Container replay failed for container <
variable>.
|
Informational message. No user intervention is
required. Contact Dell Support for assistance or intervention.
|
Internal failure—Name Space subsystem initialization
failed.
|
Informational message. No user intervention is
required. Contact Dell Support for assistance or intervention.
|
Inconsistencies were found in the Name Space. |
Please schedule a filesystem consistency check
using the DR Series system CLI
maintenance --filesystem --start_scan command.
|
System entering Maintenance mode—Name Space log
replay failed.
|
Contact Dell Support for assistance or intervention. |
System entering Maintenance Mode—Name Space transaction
failure.
|
Contact Dell Support for assistance or intervention. |
Internal failure—failed to commit Name Space transaction. |
Contact Dell Support for assistance or intervention. |
Filesystem has reached the maximum supported number
of Name Space entries.
|
Please clean up the filesystem to allow new file
and directory create operations. If this condition persists, contact
Dell Support for assistance or intervention.
|
Filesystem has recovered from a lack of available
Name Space entries.
|
Filesystem create operations will now be allowed.
Contact Dell Support for assistance or intervention.
|
Internal attributes of some files were found to
be corrupt. The DR Series system will not allow the setting or removing
of Attributes or ACLs on files that have corrupt attributes.
|
To find all files with corrupt attributes and to
clear the state, please perform a maintenance scan using the DR Series
system CLI
maintenance --filesystem --start_scan command.
Contact Dell Support for assistance or intervention.
|
System entering maintenance mode - Name Space
Log Rotation failed
|
|
File/Directory Statistics table out of sync. Switching
to maintenance mode.
|
|
Root inode of container, id <
variable>, was found to be inconsistent. Fixed the attribute, ACL on root
inode needs to be manually verified and fixed.
|
|
Replication re-sync started for container <
variable>.
|
Informational message. No user intervention is
required.
|
Replication internal re-sync started for container
<
variable>.
|
Informational message. No user intervention is
required.
|
Replication re-sync completed for container <
variable>.
|
Informational message. No user intervention is
required.
|
Replication internal re-sync completed for container
<
variable>.
|
Informational message. No user intervention is
required.
|
Internal failure creating replication snapshot
for container <
variable>.
|
If condition persists, reduce number of inodes,
or contact Dell Support for assistance or intervention.
|
Internal failure deleting replication snapshot
for container <
variable>.
|
If condition persists, reduce number of inodes,
or contact Dell Support for assistance or intervention.
|
Replication client connected for container <
variable>.
|
Informational message. No user intervention is
required.
|
Replication client disconnected for container <
variable>.
|
Verify that the ports for replication (9904, 9911,
9915, and 9916) and OST (10011 and 11000) operations have been enabled.
If issue persists, contact Dell Support for assistance or intervention.
|
Replication server connected for container <
variable>.
|
Verify that the ports for replication (9904, 9911,
9915, and 9916) and OST (10011 and 11000) operations have been enabled.
If issue persists, contact Dell Support for assistance or intervention.
|
Replication server disconnected for container
<
variable>.
|
Informational message. No user intervention is
required.
|
Replication Name Space oplog full for container
<
variable>.
|
Verify that the ports for replication (9904, 9911,
9915, and 9916) and OST (10011 and 11000) operations have been enabled.
If issue persists, contact Dell Support for assistance or intervention.
|
Replication switching to re-sync due to corrupt
replication Name Space oplog for container <
variable>.
|
|
Replication data operations log (oplog) full for
container <
variable>.
|
The DR Series system should self-correct itself.
If condition persists, reduce number of inodes, or contact Dell Support
for assistance or intervention.
|
Replication switching to re-sync due to corrupt
replication data oplog for container <
variable>.
|
|
Replication transmit log (txlog) full for container
<
variable>.
|
The DR Series system should self-correct itself.
If condition persists, reduce number of inodes, or contact Dell Support
for assistance or intervention.
|
System entering Maintenance mode due to corrupt
replication txlog for container <
variable>.
|
Collect a diagnostics log file, and open a Support
record with Dell Support for assistance.
|
System entering Maintenance mode due to replication
txlog commit error <
variable> for container <
variable>.
|
Collect a diagnostics log file, and open a Support
record with Dell Support for assistance.
|
Unable to make progress on filesystem replication
for container <
variable>.
|
Collect a diagnostics log file, and open a Support
record with Dell Support for assistance.
|
Replication syncmgr exited for container <
variable> error <
variable>.
|
Collect a diagnostics log file bundle, and open
a Support record with Dell Support for assistance.
|
Replication syncmgr event for container <
variable> error <
variable>.
|
Collect a diagnostics log file bundle, and open
a Support record with Dell Support for assistance.
|
Name Space replicator exited for container <
variable> error <
variable>.
|
Collect a diagnostics log file bundle, and open
a Support record with Dell Support for assistance.
|
Replication data replicator exited for container
<
variable> error <
variable>.
|
Collect a diagnostics log file bundle, and open
a Support record with Dell Support for assistance.
|
Replication protocol version mismatch for container
<
variable> error <
variable>.
|
Collect a diagnostics log file bundle, and open
a Support record with Dell Support for assistance.
|
Replication protocol version mismatch detected
for container <
variable>. Replication will continue with
downgraded source protocol version.
|
|
Replication delete cleanup failed for container
<
variable> error <
variable>.
|
Collect a diagnostics log file bundle, and open
a Support record with Dell Support for assistance.
|
Replication target system <
variable>
is running low on space. Replication cannot proceed further on container
<
variable>.
|
Informational message. Contact Dell Support for
assistance or intervention.
|
Replication misconfiguration detected for container
<
variable>. Replication relationship might have been deleted
forcibly on target system <
variable>.
|
Informational message. Contact Dell Support for
assistance or intervention.
|
Replication failed for container <
variable> error <
variable>.
|
Collect a diagnostics log file bundle, and open
a Support record with Dell Support for assistance.
|
Replication server failed to commit blockmap for
container <
variable>. System is entering Maintenance mode.
|
The DR Series system should self-correct itself.
If condition persists, reduce number of inodes, or contact Dell Support
for assistance or intervention.
|
Container <
variable> replication is
paused, cleaner on replica is reclaiming space.
|
Run the Cleaner on the replica container. If condition
persists, contact Dell Support for intervention or assistance.
|
Found mismatch in system software version with
peer <
variable>. Replication on source container <
variable> would be stalled.
|
|
Replication stalled on source container <
variable> due to a mismatch in system software version or network
issue with peer <
variable>.
|
|
Found mismatch in system software version with
peer <
variable>. Backup or replication on some or all target
containers would be stalled.
|
|
Received a garbled message from peer <
variable>. Connection would be dropped.
|
|
Container <
variable> replication encountered
encryption setup error.
|
|
NFS client successfully mounted <
variable>.
|
Informational message. No user intervention is
required.
|
Maximum NFS connection limit <
variable> reached, active NFS connections <
variable>.
|
You have reached the threshold limit. Reduce the
number of connections.
|
NFS client <
variable> successfully unmounted
<
variable>.
|
Informational message. No user intervention is
required.
|
NFS client <
variable> successfully unmounted
all containers.
|
Informational message. No user intervention is
required.
|
CIFS client successfully connected to container
<
variable>.
|
Informational message. No user intervention is
required.
|
CIFS client <
variable> session successfully
disconnected from container <
variable> .
|
Informational message. No user intervention is
required.
|
Maximum <
variable> connection limit <
variable> reached.
|
You have reached the threshold limit for the specified
protocol. Reduce the number of connections.
|
CIFS server failed to start <
variable>.
|
Reboot the DR Series system. If issue persists,
contact Dell Support for assistance or intervention.
|
CIFS client connected <
variable> times
to container <
variable>.
|
Reboot the DR Series system. If issue persists,
contact Dell Support for assistance or intervention.
|
CIFS server started successfully. |
Informational message. No user intervention is
required.
|
NFS server started successfully. |
Informational message. No user intervention is
required.
|
Storage usage approaching system capacity. |
Informational message. No user intervention is
required.
|
Online data verification (DataCheck) started. |
Informational message. If issue persists, contact
Dell Support for assistance or intervention.
|
Online data verification (DataCheck) suspended. |
Informational message. If issue persists, contact
Dell Support for assistance or intervention.
|
Online data verification (DataCheck) stopped. |
Informational message. If issue persists, contact
Dell Support for assistance or intervention.
|
Online data verification (DataCheck) resumed. |
Informational message. If issue persists, contact
Dell Support for assistance or intervention.
|
Online data verification (DataCheck) detected
<
variable> corruption.
|
Informational message. If issue persists, contact
Dell Support for assistance or intervention.
|
Online data verification (DataCheck) detected
<
variable> corruptions.
|
Informational message. If issue persists, contact
Dell Support for assistance or intervention.
|
Online data verification (DataCheck) failed to
start.
|
Informational message. If issue persists, contact
Dell Support for assistance or intervention.
|
Seeding device became full. |
Add new seeding device to continue. |
Seeding cannot contact the target device. |
Check to make sure that the target device is available
and write-enabled. Then remove and re-add the target device.
|
Seeding process complete. |
Informational message. No user intervention is
required.
|
System has reached space full condition, seeding
will be stopped.
|
|
Seeding failed to create Zero log entries. |
Switch to maintenance mode to correct the issue. |
Found corrupted stream on seeding device. This
error will be rectified during replication re-sync done on this seed
data.
|
Informational message. No user intervention is
required.
|
Seeding device metadata info file missing, unable
to import.
|
|
Seeding device mount not accessible. |
|
Seeding export paused as the device contains data
from another seeding job.
|
Clean up the device and re-add to continue seeding. |
Seeding encountered error. |
|
Unable to decrypt the Seeding data. |
Please check that the "password" and "encryption
type" matches the Seeding export job.
|
Seeding device deleted. |
Informational message. No user intervention is
required.
|
Seeding device added. |
Informational message. No user intervention is
required.
|
Seeding started. |
Informational message. No user intervention is
required.
|
Seeding stopped. |
Informational message. No user intervention is
required.
|
Container <
variable> added to seeding.
|
Informational message. No user intervention is
required.
|
Container <
variable> is removed while
seeding is in progress.
|
Informational message. No user intervention is
required.
|
Container <
variable> removed from seeding.
|
Informational message. No user intervention is
required.
|
Seeding job created. |
Informational message. No user intervention is
required.
|
Seeding job deleted. |
Informational message. No user intervention is
required.
|
Seed space reclamation triggered. |
Informational message. No user intervention is
required.
|
Unable to use old seed dict. Creating a new dict. |
Informational message. No user intervention is
required.
|
Unable to read bmap scid. Retry seeding after running
filesystem scan.
|
Retry seeding after running filesystem scan. |
Unable to read DS scid. Retry seeding after running
filesystem scan.
|
Retry seeding after running filesystem scan. |
Seeding device mount not accessible. Check the
CIFS mount and re-add the device to continue.
|
Check the CIFS mount and re-add the device to
continue.
|
System Event =
Type 4
|
Internal Error. Unable to load deduplication dictionary
<
variable>.
|
Use the DR Series system CLI
maintenance --configuration --reinit_dictionary command.
If this issue persists, contact Dell Support for assistance or intervention.
|
Internal Error. Unable to locate deduplication
dictionary <
variable>.
|
Use the DR Series system CLI
maintenance --configuration --reinit_dictionary command.
If issue persists, contact Dell Support for assistance or intervention.
|
Filesystem cleaner run <
variable> started.
|
Informational message. No user intervention is
required.
|
Filesystem cleaner run <
variable> completed
in <
variable> milliseconds (ms).
|
Informational message. No user intervention is
required.
|
Filesystem cleaner process encountered input/output
(I/O) errors.
|
Maintenance-based issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
Contact Dell Support as needed.
|
Failure to sync NVRAM <
variable>.
|
NVRAM hardware issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
|
Failure reading from NVRAM <
variable>.
|
NVRAM hardware issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
|
Failure writing to NVRAM <
variable>.
|
NVRAM hardware issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
|
Failure to write sync NVRAM <
variable>.
|
NVRAM hardware issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
|
Internal Error. Datastore <
variable>
length mismatch <
variable>.
|
Maintenance-based issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
Contact Dell Support as needed.
|
Data volume capacity threshold reached. |
Informational message. No user intervention is
required.
|
Out of space. Rollback of updates on object <
variable> failed. Restarting file server.
|
Maintenance-based issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
Contact Dell Support as needed.
|
Failure reading from data volume. |
Maintenance-based issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
Contact Dell Support as needed.
|
Failure writing to data volume. |
Maintenance-based issue with the DR Series system.
Check status using Maintenance mode or DR Series system CLI commands.
Contact Dell Support as needed.
|
Checksum verification on metadata failed. |
Contact Dell Support for assistance or repair
the filesystem. For repairs, see
About The DR Series
Maintenance Mode
.
|
Internal Error. Optimization engine log replay
failed.
|
Contact Dell Support for assistance or repair
the filesystem. For repairs, see
About The DR Series
Maintenance Mode
.
|
Decompression of datastore failed <
variable>.
|
Contact Dell Support for assistance or intervention. |
Internal Error. Failed to clean active datastore
<
variable>.
|
Contact Dell Support for assistance or intervention. |
Internal Error. Negative reference on datastore
<
variable>. Record type: <
variable>. Count: <
variable>.
|
Contact Dell Support for assistance or repair
the filesystem. For repairs, see the topic, “About the DR Series Maintenance
Mode.”
|
Internal Error. Data store <
variable>
contains negative stream reference count. Record type: <
variable>. Count: <
variable>.
|
Informational message. No user intervention is
required.
|
Internal Error. Data store <
variable> total reference count reached threshold. Record type: <
variable>. Count: <
variable>.
|
Informational message. No user intervention is
required.
|
Data store[%s] stream(s) marked bad. |
A chunk of data on the system failed consistency
check. An attempt will be made to correct this chunk of data.
|
Internal Error. Entering Maintenance mode due
to failure in processing logs.
|
Contact Dell Support for assistance or intervention. |
Internal Error. Failed to acquire optimizer pipeline.
Error: <
variable>.
|
Contact Dell Support for intervention or assistance. |
Internal Error. Failed to create optimizer event.
Type: <
variable>, Error: <
variable>.
|
Contact Dell Support for intervention or assistance. |
Internal Error. Task execution in fiber <
variable> timed out after <
variable> milliseconds (ms).
Restarting file server.
|
Filesystem restarted. Collect diagnostics log file
bundle, and upload diagnostics log file bundle to Dell Support.
|
Internal Error. Memory allocation failure. |
Collect diagnostics log file bundle. |
Background compression started. |
Informational message. No user intervention is
required.
|
Background compression completed. |
Informational message. No user intervention is
required.
|
Optimization initialized on container <
variable>.
|
Informational message. No user intervention is
required.
|
Optimization terminated on container <
variable>.
|
Informational message. No user intervention is
required.
|
Cleaner aborted at <
variable>.
|
The DR Series system should enter Maintenance
mode, and Cleaner process will restart.
|
Internal Error. Moving data from NVRAM to disk
failed. System is entering its Maintenance mode.
|
Informational message. No user intervention is
required.
|
System entering Maintenance Mode due to corrupt
encryption keystore. Triggering key import.
|
Run filesystem scan with verify data enabled |
Key rotation successful in internal mode |
Informational message. No user intervention is
required.
|
Key limit reached, reusing the last key |
Informational message. No user intervention is
required.
|
Filesystem encryption setting changed |
Informational message. No user intervention is
required.
|
Filesystem Cleaner process started as per schedule
(will be active until <
variable>).
|
Informational message. No user intervention is
required.
|
Filesystem Cleaner process stopped as per schedule
(will restart at <
variable>).
|
Informational message. No user intervention is
required.
|
Filesystem cleaner is paused, to speed up disk
maintenance (e.g. Rebuild / Background Init) activities.
|
Informational message. No user intervention is
required.
|
System entering Support Mode due to keystore repair
failure, both primary and backup keystore are corrupt
|
|
System entering Support Mode due to keystore empty
failure, both primary and backup keystore are empty or removed
|
|
System Event =
Type 5
|
System shutdown initiated by administrator. |
Informational message. No user intervention is
required.
|
System reboot initiated by administrator. |
Informational message. No user intervention is
required.
|
Start system upgrade to version <
variable>.
|
Informational message. No user intervention is
required.
|
System name changed to <
variable>.
|
Informational message. No user intervention is
required.
|
System date changed to <
variable>.
|
Informational message. No user intervention is
required.
|
System time zone changed to <
variable>.
|
Informational message. No user intervention is
required.
|
Password changed for user: administrator. |
Informational message. No user intervention is
required.
|
NTP server <
variable> added.
|
Informational message. No user intervention is
required.
|
NTP server <
variable> deleted.
|
Informational message. No user intervention is
required.
|
NTP service enabled. |
Informational message. No user intervention is
required.
|
NTP service disabled. |
Informational message. No user intervention is
required.
|
User data destroyed using CLI command. |
Informational message. No user intervention is
required.
|
User <
variable> enabled.
|
Informational message. No user intervention is
required.
|
User <
variable> disabled.
|
Informational message. No user intervention is
required.
|
Networking interfaces restarted. |
Informational message. No user intervention is
required.
|
DHCP enabled: IP address assigned by DHCP. |
Informational message. No user intervention is
required.
|
Static IP address <
variable> assigned.
|
Informational message. No user intervention is
required.
|
Network interface bonding mode set to <
variable>.
|
Informational message. No user intervention is
required.
|
Network MTU size set to <
variable>.
|
Informational message. No user intervention is
required.
|
System name set to <
variable>.
|
Informational message. No user intervention is
required.
|
Email relay host set to <
variable> for
email alerts.
|
Informational message. No user intervention is
required.
|
Recipients for email alerts set to <
variable>.
|
Informational message. No user intervention is
required.
|
Recipient <
variable> added to receive
email alerts.
|
Informational message. No user intervention is
required.
|
Recipient <
variable> is no longer receiving
email alerts.
|
Check whether email recipient still exists, or
if mailbox is full.
|
Administrator information set to <
variable> for email alerts.
|
Informational message. No user intervention is
required.
|
Test email sent. |
Informational message. No user intervention is
required.
|
Joined the Windows Active Directory domain <
variable>.
|
Informational message. No user intervention is
required.
|
Left the Windows Active Directory domain <
variable>.
|
Informational message. No user intervention is
required.
|
System diagnostics package <
variable> deleted.
|
Informational message. No user intervention is
required.
|
All diagnostic packages deleted. |
Informational message. No user intervention is
required.
|
System diagnostic package <
variable>
is copied off the system.
|
Informational message. No user intervention is
required.
|
System statistics reset by administrator. |
Informational message. No user intervention is
required.
|
System diagnostic package <
variable>
is collected.
|
Informational message. No user intervention is
required.
|
System diagnostics space usage exceeded threshold.
Auto cleaning oldest package: <
variable>.
|
Informational message. No user intervention is
required.
|
Internal Error. CIFS server cannot access file
service.
|
Contact Dell Support for intervention or assistance.
Collect diagnostics log file bundle, and upload to Dell Support.
|
Host <
variable> added to SNMP alert recipient
list.
|
Informational message. No user intervention is
required.
|
Host <
variable> deleted from SNMP alert
recipient list.
|
Informational message. No user intervention is
required.
|
Host <
variable> enabled for SNMP alerts.
|
Informational message. No user intervention is
required.
|
Host <
variable> disabled for SNMP alerts.
|
Informational message. No user intervention is
required.
|
User <
variable> logged into the system.
|
Informational message. No user intervention is
required.
|
CIFS user <
variable> added.
|
Informational message. No user intervention is
required.
|
CIFS user <
variable> deleted.
|
Informational message. No user intervention is
required.
|
Password changed for CIFS user <
variable>.
|
Informational message. No user intervention is
required.
|
System upgrade completed <
variable>.
|
Informational message. No user intervention is
required.
|
Cleared foreign configuration on disk <
variable>.
|
Informational message. No user intervention is
required.
|
User <
variable> logged into the system.
|
Informational message. No user intervention is
required.
|
Disk <
variable> configured as hot spare.
|
Informational message. No user intervention is
required.
|
Telnet service enabled. |
Informational message. No user intervention is
required.
|
Telnet service disabled. |
Informational message. No user intervention is
required.
|
DNS settings updated with primary <
variable>, secondary <
variable>, and suffix <
variable>.
|
Informational message. No user intervention is
required.
|
System initialized successfully. |
Informational message. No user intervention is
required.
|
<
variable> added with entitlement id
<
variable>.
|
Informational message. No user intervention is
required.
|
Security privilege(s) changed for <
variable>.
|
Informational message. No user intervention is
required.
|
User <
variable> logged into the administrative
web interface.
|
Informational message. No user intervention is
required.
|
Network interface(s) <
variable> enabled.
|
Informational message. No user intervention is
required.
|
Network interface(s) <
variable> disabled.
|
Informational message. No user intervention is
required.
|
SMBD backup traffic interface(s) <
variable> do not have an IP.
|
|
DR2000v registered successfully. |
Informational message. No user intervention is
required.
|
DR2000v unregistered successfully. |
Informational message. No user intervention is
required.
|
DR2000v data storage expanded by 1 TiB. |
Informational message. No user intervention is
required.
|
Miscellaneous Invalid/Last Event. |
Informational message. No user intervention is
required.
|
System Event =
Type 6
|
File system check started. |
Informational message. No user intervention is
required.
|
File system check completed successfully. No inconsistencies
were found.
|
Informational message. No user intervention is
required.
|
File system check found some inconsistencies. |
The DR Series system Maintenance mode repair process
should resolve this. If the problem persists, contact Dell Support
for assistance or intervention.
|
File system repair started. |
Informational message. No user intervention is
required.
|
File system repair completed. |
Informational message. No user intervention is
required.
|
File system check stop requested. |
Informational message. No user intervention is
required.
|
One (or more) file(s) were deleted as part of
the repair process.
|
Informational message. No user intervention is
required. To verify, please use the DR Series system CLI
maintenance
--filesystem --repair_history verbose
command.
|
One or more file(s) were deleted as part of the
repair process for container <
variable>. Replication will
be stopped for this container.
|
Informational message. No user intervention is
required.
|
One or more file(s) were deleted as part of the
repair process for container <
variable>. Re-sync has been
initiated for this container.
|
Informational message. No user intervention is
required.
|
System Event =
Type 7
|
RDA server started successfully. |
Informational message. No user intervention is
required.
|
RDA server failed to start. |
Restart the RDA server. If issue persists, contact
Dell Support for assistance or intervention.
|
RDA server stopped successfully. |
Informational message. No user intervention is
required.
|
<
Variable> client authentication failed.
|
Retry the OST client authentication. If issue persists,
contact Dell Support for assistance or intervention.
|
<
Variable> Logical Storage Unit (LSU)
quota exceeded <
variable>.
|
Informational message. Reduce the number of LSUs.
If issue persists, contact Dell Support for assistance or intervention.
|
<
Variable> backup failed <
variable>.
|
Retry the OST backup operation. If issue persists,
contact Dell Support for assistance or intervention.
|
<
Variable> Opdup failed <
variable>.
|
The OST optimized duplication process failed.
If issue persists, contact Dell Support for assistance or intervention.
|
<
Variable> Restore failed <
variable>.
|
The OST restore process failed. If issue persists,
contact Dell Support for assistance or intervention.
|
RDA connections exceeded the maximum limit; count:
<
variable>, maximum limit: <
variable>.
|
Informational message. Reduce the number of OST
connections. If issue persists, contact Dell Support for assistance
or intervention.
|
Connection from the <
variable> client
<
variable> aborted.
|
Informational message. No user intervention is
required.
|
RDA client protocol version is not supported. |
Informational message. No user intervention is
required. Check for the supported OST client versions in the
Dell
DR Series System Interoperability Guide
.
|
System is entering the Maintenance mode: <
variable> LSU information file is corrupted.
|
Informational message. No user intervention is
required. If issue persists, contact Dell Support for assistance or
intervention.
|
System is entering the Maintenance mode: <
variable> image information is corrupted.
|
Informational message. No user intervention is
required. If issue persists, contact Dell Support for assistance or
intervention
|
<
variable> client connection was reset.
|
Informational message. No user intervention is
required.
|
System is entering the Maintenance mode: RDA meta
directory is corrupted.
|
Informational message. No user intervention is
required.
|
RDA server initialization failed. |
Informational message. No user intervention is
required.
|
RDA server initialization was successful. |
Informational message. No user intervention is
required.
|
System entering Maintenance Mode - RDA txlog full,
LSU <
variable>.
|
Informational message. No user intervention is
required.
|
System entering Maintenance Mode - RDA txlog operation
error <
variable>, LSU <
variable>.
|
Informational message. No user intervention is
required.
|
System entering Maintenance Mode - RDA txlog roll-forward
error <
variable>, LSU <
variable>.
|
Informational message. No user intervention is
required.
|