Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Remove the PERC H750 adapter SAS

Prerequisites

CAUTION:Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
NOTE:It is recommended that you always use a static mat and static strap while working on components in the interior of the system.

Steps

  1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and peripherals.
  2. Open the system.
  3. Locate the PERC card on the system board.
    CAUTION:To prevent damage to the card, you must hold the card by its edges only.
  4. Lift the card to remove it from the connector on the system board.
  5. Disconnect the SAS cables connected to the card:
    1. Press down and hold the metal tab on the SAS cable connector.
    2. Pull the SAS cable out of the connector.
  6. Replace the storage controller card and connect the cable. For more information on installing the card, see Install the H750 adapter SAS.
  7. Close the system.
  8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
    Figure 1. Remove PERC H750 adapter SAS
    Remove the PERC H750 adapter SAS