Configuring a Guest VLAN

If the supplicant does not respond within a determined amount of time ( [reauth-max + 1] * tx-period), the system assumes that the host does not have 802.1X capability and the port is placed in the Guest VLAN.

Configure a port to be placed in the Guest VLAN after failing to respond within the timeout period using the dot1x guest-vlan command from INTERFACE mode. View your configuration using the show config command from INTERFACE mode or using the show dot1x interface command from EXEC Privilege mode.

Example of Viewing Guest VLAN Configuration

Dell(conf-if-gi-1/2)#dot1x guest-vlan 200
                                 Dell(conf-if-gi-1/2)#show config
                                 !
                                 interface GigabitEthernet 1/2
                                 switchport
                                 
                                 dot1x guest-vlan 200
                                 no shutdown
                                 Dell(conf-if-gi-1/2)#
                              