跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Enabling BFD Globally

You must enable BFD globally on both routers.

To enable the BFD globally, use the following command.
Enable BFD globally. CONFIGURATION mode bfd enable

Example of Verifying BFD is Enabled

To verify that BFD is enabled globally, use the show running bfd command.

The bold line shows that BFD is enabled.

R1(conf)#bfd ?
                                 enable               Enable BFD protocol
                                 protocol-liveness    Enable BFD protocol-liveness
                                 R1(conf)#bfd enable
                                 
                                 R1(conf)#do show running-config bfd
                                 !
                                 
                                 bfd enable
                                 R1(conf)#
                              