NOTE:# The Riser R3B is shipped with the GPU FL kit, however riser R3B does not support GPU.
NOTE:1 The configuration 3-1 supports GPU only on slots 2 and 7.
NOTE:$ Use power cable PN CXV0X for NVIDIA H100/L40 in slot 2 and power cable PN FGTM1 for H100/L40 in slot 7. The NVIDIA H100/L40 power cable is 450 W capable.
Table 2. Components in the half length (HL) GPU kitThe table describes the components in the half length (HL) GPU kit.
Before you begin, follow the
safefy guidelines
and
before working inside the system instructions.
Remove the standard cooling fans and install the High performance (silver grade) fan or high-performance (gold grade) fan cooling fans.
NOTE:Refer to the cooling fan and foam requirement matrix for the cooling fan and foam requirement for different configurations.
Table 3. Cooling fan and foam requirement matrixThe table describes foam requirement for the system.
System configuration
Cooling fan
Foam requirement
w/GPU
w/GPU + Barlow Pass DIMM
w/GPU
w/GPU + Barlow Pass DIMM
8 x 2.5-inch NVMe
HPR SLVR
HPR GOLD
No
Yes
16 x 2.5-inch SAS/SATA
HPR GOLD
HPR GOLD
Yes
Yes
16 x 2.5-inch NVMe
HPR GOLD
HPR GOLD
Yes
Yes
24 x 2.5-inch SAS/SATA
HPR GOLD
HPR GOLD
Yes
Yes
16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe
HPR GOLD
HPR GOLD
Yes
Yes
HPR - High Performance, SLVR - Silver
NOTE:For more information about supported cooling fans matrix, see the thermal restriction section in Dell EMC PowerEdge R750 Technical Specifications on the product documentation page.
NOTE:12 x 3.5 inch and rear drive configuration systems do not support GPU card.
Remove the heat sink and install the required t-type heat sink.
NOTE:All GPU cards require t-type heat sink and GPU shroud, irrespective of the length.
Remove the air shroud and install the GPU air shroud.
Remove the GPU air shroud top cover.
NOTE:The GPU air shroud top cover is part of the GPU air shroud.
NOTE:For information about riser slot location on the system board, see the System board jumpers and connectors topic.
If applicable, connect the power cables to the GPU. To know the connectors for GPU on the system board, see the System board jumpers and connectors topic.
Refer to the GPU power cable matrix to know about the requirement of cable for the GPU.
Table 4. GPU power cable matrixThe tables describe GPU power cable that is required for the GPU installation.
Category
Supported GPUs
Type
Vendor
Cable
Cable quantity
GPU
NVIDIA T4 and A2
HH and HL (FH and LP brackets)
NVIDIA
Not required
Not required
GPU
Intel ATS-M75
HH and HL (FH and LP brackets)
Intel
Not required
Not required
GPU
NVIDIA M10, A10, A30, A40, A16, A100, and A800
FH and FL
NVIDIA
8 pin cable
1 piece per GPU riser
GPU
NVIDIA H100, L40
FH and FL
NVIDIA
16 pin cable
1 piece per GPU riser
HH - Half Height, HL - Half Length, FH - Full Height, FL - Full Length
NOTE:Maximum of two double width GPUs with power cables or a maximum of eight single width GPUs are supported in a system.
Install the full length expansion card riser or half height expansion card riser. See GPU kit components table for supported GPU risers.
Install the GPU air shroud filler.
Install the GPU air shroud top cover.
Install the foam on the system cover. To install the foam,
Place the system cover with the System Information Label (SIL) side facing up.
For easier handling, peel off a small section of the adhesive cover and align the foam with the system cover.
Remove rest of the adhesive cover, and install foam on the system cover.
Press along the length of the foam to ensure that it is firmly affixed to the system cover.
After installing, follow the After working inside the system instructions.