Artikler
Ugyldig indtastning. Brug kun bogstaver, tal og specialtegn undtagen <>)(%/;,=#-/*
30 ud af 45 vist
45 ud af 45 vist
Dette dokument fremhæver minimumversioner samt anbefalede og nyeste kodeversioner for Dell Technologies Enterprise- og datacenterinfrastrukturprodukter. Dell evaluerer og overvåger omhyggeligt kodeimplementeringsdata for at sikre, at produktudgivelser lever op til vores strenge forventninger om at give vores kunder pålidelige produkter og løsninger.
Opdateret: juli 28, 2026
Id: 000205512
Oplysninger om CRU-videoer (Customer Replaceable Unit) om Dell Technologies VxFlex Ready-nodeprodukter
Opdateret: maj 22, 2026
Id: 000262249
Affected products after NX OS 9.4.2a upgrade:
Cisco MDS 9000 NX-OS and SAN-OS Software, Cisco MDS 9100 Series Multilayer Fabric Switches, Cisco MDS 9200 Series Multiservice Switches, Cisco MDS 9300 Series Multilayer Fabric Switches, Cisco MDS 9500 Series Multilayer Directors, Cisco MDS 9700 Series Multilayer Directors
Opdateret: maj 23, 2026
Id: 000353884
This article contains information about customer replaceable unit (CRU) videos for Dell Technologies VNX and VNXe products.
Opdateret: maj 22, 2026
Id: 000262248
Information about customer replaceable unit (CRU) videos for Dell Technologies PowerProtect and Data domain products
Opdateret: maj 22, 2026
Id: 000262244
Information about customer replaceable unit (CRU) videos for Dell Technologies Powerflex products
Opdateret: maj 22, 2026
Id: 000262242
Information about customer replaceable unit (CRU) videos for Dell Technologies ECS products
Opdateret: maj 22, 2026
Id: 000262239
Information about customer replaceable unit (CRU) videos for Dell Technologies Connectrix products
Opdateret: maj 22, 2026
Id: 000262233
Connectrix Cisco MDS: Activating or Importing smart license for No Connectivity to CSSM and No CSLU
Here we have a switch and CSSM disconnected from each other without any other intermediary CSLU or components.
All communication is in the form of uploaded and downloaded files.
Example: When there is no remote connectivity to the switch (Dark site).
Opdateret: maj 19, 2026
Id: 000217941
This article provides steps to back up and restore Zones using DCNM.
Opdateret: maj 19, 2026
Id: 000217625
Dette problem opstår, når overvågningsloggene udfyldes for switchene, modtager e-mailmeddelelser fra switchene, eller når en switch har været inaktiv i nogen tid, og der ikke genereres hændelser.
Opdateret: maj 18, 2026
Id: 000215691
This KB provides steps to collect switch #show tech-support through DCNM.
Opdateret: maj 18, 2026
Id: 000215515
Formålet med Smart Zoning er at reducere mængden af administrative omkostninger, der er påkrævet for at tilføje nye værter til SAN med tilføjelsen af et par nøgleord.
Opdateret: maj 16, 2026
Id: 000206541
Få mere at vide om, hvordan analysedashboardet til MyService360-tjenester integrerer CloudIQ Health Score i visningerne af installationsbasen. Dette strømliner administration af tjenester og produkttilstand udført af it-administratorer ved hjælp af MyService360- og CloudIQ-portalerne. Bekræft understøttede produkter efter portal, og få adgang til nyttige CloudIQ-ressourcer.
Opdateret: maj 16, 2026
Id: 000206380
Downgrade from 8.5.1 to earlier 8.x versions fails to execute due to compatibility error in snmp config.
Opdateret: maj 16, 2026
Id: 000206287
Domain IDs uniquely identify a switch in a Virtual Storage Area Network (VSAN). A switch may have different domain IDs in different VSANs. The domain ID is part of the overall Fibre Channel (FC) ID.
The configured domain ID can be preferred or static. By default, the configured domain ID is 0 (zero) and the configured type is preferred. Domain IDs can range from 1 to 239.
The 0 (zero) value can be configured only if you use the preferred option.
Opdateret: maj 15, 2026
Id: 000203078
End devices unable to communicate - FCNS rejecting to all FC CT queries with 'logical busy'. Because end devices cannot get proper responses to their queries, they will not be able to communicate with one another.
Opdateret: maj 13, 2026
Id: 000197900
Switch streaming "%PLATFORM-1-PFM_ALERT: FAN_BAD" related events for absent fans
Opdateret: maj 10, 2026
Id: 000188724
Connectrix MDS : 97xx Chassis information missing with error message %PLATFORM-2-PS_UNSUPPORTED
Opdateret: maj 09, 2026
Id: 000185047
SCG, Base64-kodning, Cisco, ESRS-script, adgangskode Base64-kodning
Opdateret: maj 08, 2026
Id: 000183204
Ved en zoneaktivering logges alle HBA'er, der er i samme zone som en VPLEX front-end-port, ud og mister en sti. ESX-værter kan hænge og kræve en genstart for at blive gendannet. [Scott - berører dette kun ESX-værter? I resuméet står der "Alle HBA'er i samme zone som en VPLEX". Kan vi begrænse dette udelukkende til ESX-værter, eller omformulere og skrive "Værter kan hænge og kræve en genstart for at blive gendannet?]
Opdateret: maj 07, 2026
Id: 000181952
How to perform NX-OS upgrade on the MDS switches
Opdateret: maj 07, 2026
Id: 000180494
Opgradering af switche i MDS 9000-serien mislykkes på grund af konfigurationssession. Afbryd konfigurationssessionen for at tillade opgradering at blive fuldført.
Opdateret: marts 26, 2026
Id: 000181987
I en 32 Gbps MDS-platform, %SYSMGR-3-HEARTBEAT_FAILURE dræbes tjenesten 'lc_port_mgr' tilfældigt med signal 6, muligvis flere gange.
Opdateret: marts 04, 2026
Id: 000280977
Her er trinnene til at konfigurere tx-/rx-datarate-politikken på en MDS-switch.
Disse trin er ikke forstyrrende.
De påvirker ikke produktionstrafikken; De ændres kun, når switchen registrerer oplysninger.
Herefter vil der være en ny aktiv politik, der har de samme to tællere som den tidligere slowdrain-politik med den ekstra tx-/rx-dataratetæller.
Alle porte, der går til 80% Tx eller Rx udnyttelse i 10 sekunder, får en advarsel.
Bemærk: Dette er en almindelig anmodning, TAC fremsætter, når kunder er bekymrede over ydeevnen i en struktur.
Opdateret: februar 24, 2026
Id: 000189878
FC-slutenhedens port, der er direkte tilsluttet en MDS Fabric-switch, går til fejlbehæftet tilstand efter ISSU/ISSD-aktivitet.
Betingelser:
Dette problem gælder kun for følgende fabric-switche:
Cisco MDS 9132T
Cisco MDS 9148S
Cisco MDS 9148T
Cisco MDS 9220i
Cisco MDS 9396S
Cisco MDS 9396T
Desuden er ISSU/ISSD mellem to af følgende Cisco NX-OS-versioner:
8.4, stk. 1, og artikel 8.4, stk. 1a)
8.4, stk. 2, artikel 8.4, stk. 2a, artikel 8.4, stk. 2b, og artikel 8.4, stk. 2c)
8.5(1)
Opdateret: februar 24, 2026
Id: 000192572
Int fc1/17~32 er på M9XT-FC1632 Port Expansion Module (PEM), da deres portlicenser ikke kunne frigives.
Opdateret: oktober 28, 2025
Id: 000383027
Kan ikke SSH for at skifte
Opdateret: oktober 23, 2025
Id: 000055655
Dell Connectrix MDS Cisco remediation is available for CLI vulnerability that could be exploited by malicious users to compromise the affected system.
Opdateret: oktober 13, 2025
Id: 000379436
Dell Connectrix (Cisco) MDS DCNM remediation is available for an NX-OS vulnerability that may be exploited by malicious users to compromise the affected system.
Opdateret: september 18, 2025
Id: 000201621