Denne artikel indeholder oplysninger om patchopdateringerne til Dell Technologies PowerProtect Data Manager-enhedsversion 5.19.1.
Opdateret: maj 23, 2026
Id: 000333850
A disk failure caused the enclosure slot to be disabled, triggering PowerProtect One DM5510 (model) Alert EVT-PHYM-00001 (alert code) due to continuous discovery.
Opdateret: august 20, 2026
Id: 000404199
HostDiskNotOnline - Disk at slot location <Location Number> (Enclosure <Enclosure Number>, Disk <Disk Identifier>, Serial <DiskSerialNumber>) is present but not in use; triggered PPDMA DM5510 Alert EVT‑STORAGE‑00038. No reconstruction was detected.
Opdateret: august 20, 2026
Id: 000404198
An Operating System (OS) drive has failed or is about to fail, triggering PPDMA DM5510 Alert EVT‑STORAGE‑00037; the system is in a critical state and will shut down if another OS drive fails. Replace or copy‑recover the failed OS drive.
Opdateret: august 20, 2026
Id: 000404197
Data deletion in the active tier exceeded the threshold, triggering a PPDMA DM5510 alert (EVT‑SECURITY‑00053) and indicating a mass deletion risk in the cloud tier; refer to the security guide for remediation.
Opdateret: august 20, 2026
Id: 000404196
PowerProtect One DM5510 generated alert EVT-SECURITY-00052 (Event Security) indicating a mass deletion risk in the active tier; refer to the security guide for remediation.
Opdateret: august 20, 2026
Id: 000404195
Alert EVT-NETM-00019 indicates the network card in slot M of a PowerProtect One DM5510 is missing; reseat the card.
Opdateret: august 20, 2026
Id: 000404194
Input/Output (I/O) module failed in Enclosure <Enclosure Number>, Slot <Slot Number> due to <Cause>. Alert PPDMA DM5510 EVT‑NETM‑00011A indicates a Media Access Control (MAC) fault; the module will not function correctly.
Opdateret: august 20, 2026
Id: 000404193
The network interface card (NIC) is installed in an invalid slot, triggering PPDMA DM5510 Alert EVT‑NETM‑00006 (Slot=<Slot Number>, DeviceName=<DeviceName>, ValidSlots=<ValidSlots>). Install the NIC in a designated slot.
Opdateret: august 20, 2026
Id: 000404192
Security clock skew violation detected PPDMA DM5510 Alert Event File System (EVT-FILESYS-00025) indicates that the file system is disabled and cannot be re‑enabled until system time is corrected within the configured skew threshold.
Opdateret: august 20, 2026
Id: 000404191
File system cannot start due to an internal condition (PPDMA DM5510 Alert Event File System 00017).
Opdateret: august 20, 2026
Id: 000404190
PowerProtect One DM5510 reports alert EVT-ENVIRONMENT-00065: power supply module status shows AC and DC pass/fail. AC pass/DC fail → PSU failed, replace. AC fail/DC fail → input PSU unavailable, check cables/LED, replace with working unit; shut down if all PSUs alert. Contact Dell support if the issue persists.
Opdateret: august 20, 2026
Id: 000404189
Secondary Link Control Card (LCC) module failed in Enclosure <Enclosure Number> due to <Cause>, generating error PPDMA DM5510 EVT-ENVIRONMENT-00060
Opdateret: august 20, 2026
Id: 000404188
PowerProtect One DM5510 reported alert EVT-ENVIRONMENT-00059: the Input/Output (IO) personality module has failed in the specified enclosure, causing potential unexpected behavior; replace the module.
Opdateret: august 20, 2026
Id: 000404186
A fault (PPDMA DM5510 EVT‑ENVIRONMENT‑00058) was detected in the I/O expansion module; the module failed in Enclosure <#> for cause <#>, potentially causing unexpected system behavior.
Opdateret: august 20, 2026
Id: 000404185
PowerEdge: Fan Failure Alert EVT-ENVIRONMENT-00057 - Identify Failed Fan and Replace.
Opdateret: august 20, 2026
Id: 000404184
Correctable errors exceeded the critical threshold on Enclosure <Enclosure ID>, Field Replaceable Unit (FRU) <ID>. Symptom: PowerProtect One DM5510 Alert EVT-ENVIRONMENT-00054 Cause: may indicate hardware failure.
Opdateret: august 20, 2026
Id: 000404182
Fejl BAT0012 angiver lagerbatteriet til diskdrevbåsen <arg1> på en Dell PowerEdge DM5510 mislykkedes. En sandsynlig årsag er en termisk relateret fejl i PowerEdge RAID-controllerbatteriet (PERC). Kontrollere batteriinstallationen og gennemgå systemlogfiler for termiske hændelser.
Opdateret: august 19, 2026
Id: 000403228
Fejl BAT0017 angiver, at <arg1> batteriet svigter på PowerProtect One DM5510; tjek batteriet; Systemindstillingerne bevares muligvis, hvis indgangsstrømmen forbliver tilsluttet.
Opdateret: august 19, 2026
Id: 000403230
En CTL40-advarsel angiver en multi-bit-fejl under læsning/skrivning. Multi-bit fejl betyder normalt datatab; Hvis der under skrivning er tab sikkert. Udskift Dual Inline Memory Module (DIMM) i controllerbatteriet, og gendan data fra backup.
Opdateret: august 19, 2026
Id: 000404178
En ECC-fejl (Single-bit Error Correcting Code) viser, at det angivne DIMM (Dual Inline Memory Module) er kritisk forringet. Datatab eller beskadigelse kan forekomme. Udskift DIMM-modulet med det samme; Det er en del af controllerens batteripakke.
Opdateret: august 19, 2026
Id: 000404179
En DIMM-fejl (Dual Inline Memory Module) udløser en PowerProtect One DM5510 Alert CTL47 single-bit fejl i ECC-koden (Error Correcting Code). Dette kan medføre tab eller beskadigelse af data. Udskift DIMM-modulet med det samme (det er en del af controllerbatteriet).
Opdateret: august 19, 2026
Id: 000404180
PPDMA: Løs valideringsfejl i EVT-ENCRYPTION-00007-krypteringsnøgler og filsystemlås.
Opdateret: august 19, 2026
Id: 000404181
Beskyttelseslageret er fuldt; PowerProtect En DM5510 genereret advarsels STR0006 der angiver 100 % brugt kapacitet. ledig plads eller udvide lageret; Kontakt Dell Support, hvis det er nødvendigt.
Opdateret: august 19, 2026
Id: 000403167
Strømforsyning <number> mislykkedes.
Opdateret: august 19, 2026
Id: 000403170
Blæserfejl registreret på strømforsyning <arg1>.
Opdateret: august 19, 2026
Id: 000403171
PowerProtect Data Manager modtager meddelelsen "Kabinet" <Enclosure Number> Stik til strømforsyningsenhedskabel (PSU)
Opdateret: august 19, 2026
Id: 000403173
En enhed er blevet defekt, og systemet fungerer ikke længere i optimal tilstand.
Opdateret: august 19, 2026
Id: 000403177
Fejl PDR1001 indikerer en fejl på drevet <arg1> i diskdrevbåsen <arg2>. Controlleren har taget disken offline. Fjern drevet, og sæt det på plads; Hvis den forbliver offline, skal du kontakte Dells kundesupport i henhold til produktdokumentationen.
Opdateret: august 19, 2026
Id: 000403196
PDR12-initialisering mislykkedes; disken viser et rødt "X", der angiver en harddiskfejl eller -beskadigelse. Udskift den defekte disk, og genstart derefter initialiseringen.
Opdateret: august 19, 2026
Id: 000403199