This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  February 23, 2026 ID: 000205512

This article provides information about supported patches and service releases for OneFS and the HealthCheck system.
Updated:  February 20, 2026 ID: 000184794

Isilon: NANON Clusters: Process isi_audit_cee of service isi_audit_cee has failed to restart after multiple attempts - Event ID: 400030001
Updated:  February 24, 2026 ID: 000173114

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  February 24, 2026 ID: 000185734

Compliance mode requires slight changes to Support's usual Tcpdump commands.
Updated:  February 23, 2026 ID: 000019451

How to identify duplicate Service Principal Names in Active Directory, which can cause Kerberos authentication to fail.
Updated:  February 23, 2026 ID: 000032723

OneFS includes a licensed feature called SnapshotIQ. Even if the feature is unlicensed, OneFS might still create snapshots for use by other processes and features, such as File System Analytics (FSA). Snapshots are created in ".Snapshot" directories. Depending on the cluster settings and the client used to view the file system, some or all these directories are visible and accessible.
Updated:  February 23, 2026 ID: 000018962

This article provides an estimation on scheduling lead time when booking your upgrade with RPS.
Updated:  February 23, 2026 ID: 000021599

Event "A firmware update has not been completely applied" received, even when the firmware version on the component is correct.
Updated:  February 20, 2026 ID: 000055100

An issue with earlier versions of the firmware on the Mellanox5-EN0 device, which is found exclusively in F810 nodes, can force these nodes to unexpectedly cold-reboot when a warm reboot is requested or triggered by a panic or other error. If the peer node is also cold rebooted before the affected node can retrieve its journal, the journal on both nodes may be lost.
Updated:  February 19, 2026 ID: 000207184

Troubleshoot PowerScale OneFS slow performance with our comprehensive guide on network configuration, processing loads, and monitoring with InsightIQ for improved cluster efficiency.
Updated:  February 18, 2026 ID: 000015384

This article explains how to configure SmartConnect zone settings and a Windows DNS server for SmartConnect zone name resolution.
Updated:  February 18, 2026 ID: 000162644

Remote Proactive Services - Isilon/PowerScale Upgrade Plan
Updated:  February 18, 2026 ID: 000021012

This article explains how to promote Company Administrators.
Updated:  February 18, 2026 ID: 000374126

This article explains Dell guidelines on company administrator assignment.
Updated:  February 17, 2026 ID: 000379388

Issue: Bucket size on cloud target can remain unchanged after initiating a cloud recall.
Updated:  February 16, 2026 ID: 000019444

Dell has a Customer Replaceable Unit (CRU) program for many of our hardware systems. The CRU program allows customers to replace designated hardware components. For a list of the hardware components that are designated as CRU for a specific hardware system, go to the Dell Warranty and Maintenance Page.
Updated:  February 16, 2026 ID: 000187496

When querying the size of a quota, the container size reported represents the quota domain, which also includes the export or share. Quotas can be set to report the hard quota size to provide a more accurate view of quota usage. This can be accomplished using the OneFS web administration interface, but for large amounts of quota domains, this can be time-consuming and inefficient. This article provides procedures for using the command line to set the quotas to report the hard quota size.
Updated:  February 16, 2026 ID: 000018975

How to fix Unisphere for VMAX (EEM), SRDF Virtual Witness does not show alive. Error: "Did not find any vWitnesses with a heart beat"
Updated:  February 16, 2026 ID: 000026876

When a node unexpectedly reboots, it writes a minidump file (also called vmcore dump) to the /var/crash partition. In some circumstances, the node might fail to write the minidump file onto /var/crash partition, in that case, it must be manually retrieved. This article explains how to manually retrieve the minidump file from the node.
Updated:  February 13, 2026 ID: 000155772

Steps to recursively delete multiple files from an Enterprise SmartLock directory.
Updated:  February 13, 2026 ID: 000020969

In rare circumstances, SyncIQ can report replicating more data than exists in the source dataset.
Updated:  February 12, 2026 ID: 000032506

Configure SyncIQ policies with the same source path to use a common snapshot.
Updated:  February 12, 2026 ID: 000069668

When NetWorker uses Isilon as a backup destination and is configured to create snapshots for the backups, those snapshots show as Never for the expiration date. The expiration time configured in the Snapshot policy on NetWorker does not take effect.
Updated:  February 11, 2026 ID: 000015389

While configuring Cloudpool Account for the first time or modifying an existing one to use SSL, error is reported.
Updated:  February 11, 2026 ID: 000187112

Issue: While the job engine is disabled, mcp does not attempt to start isi_cpool_d, and isi_cpool_io_d. This is because the mcp configuration lists both isi_km_d and isi_job_d as dependencies. If the cluster is rebooted while the the job engine is disabled, it may result in data unavailability as multiple services in the likewise container will be unable to start.
Updated:  February 11, 2026 ID: 000175081

There are certain situations or scenarios where a quota hard limit may be unexpectedly exceeded.
Updated:  February 11, 2026 ID: 000214127

After the AVScan completes, an event gets generated if there are any threats detected. This article explains what the event-generated means after the successful AVScan run.
Updated:  February 11, 2026 ID: 000064791

This KB article describes the Process isi_drive_repurpose_d not running on any node condition.
Updated:  February 10, 2026 ID: 000053733

Sometimes Gen6 nodes generate spurious power supply faults. There are two types of alerts caused by separate issues requiring different resolution steps.
Updated:  February 10, 2026 ID: 000057405