This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  September 10, 2026 ID: 000205512

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  September 10, 2026 ID: 000502480

Only Panduit G5/G6/G7 Power Distribution Unit (PDU) has Logs Available. Every Generation Before This Does Not Have This Feature.
Updated:  September 14, 2026 ID: 000311515

This procedure is applicable if the VMware vSphere distributed switch is installed. If the VMware vSphere distributed switch is not installed, skip this procedure.
Updated:  September 14, 2026 ID: 000315113

Upgrading the gateway from 3.x to 4.x, requires the addition of the "MDM" certificate to the MDMs; otherwise, we cannot connect the MDM using scli.
Updated:  September 14, 2026 ID: 000226262

SDS remains disconnected after generating a new certificate due to an OS conversion.
Updated:  September 14, 2026 ID: 000243234

SSL Certificate Verify Failed - Failed to Bootstrap
Updated:  September 14, 2026 ID: 000504990

CloudLink: Versions Numbers for CloudLink and Their Agents
Updated:  September 14, 2026 ID: 000251011

This article lists the correct steps to update MVMs OS password for single management node deployment
Updated:  September 11, 2026 ID: 000507728

This article provides on the DRR (Data Reduction and Replication) Guarantee Program.
Updated:  September 10, 2026 ID: 000506731

Dell iDRAC Service Module (dcism) versions earlier than 6.1 contain a defect that causes thousands of firewalld reloads per day, resulting in MDM disconnects, SDS decouples, and SCLI login failures on Dell PowerFlex nodes.
Updated:  September 10, 2026 ID: 000495738

This article explains how to import and export the integrated Dell Remote Access Controller iDRAC7, iDRAC8, and iDRAC9 License.
Updated:  September 09, 2026 ID: 000145345

When a process or kernel module initiates communication over the network, a local port is allocated from the ephemeral port range as part of the socket.
Updated:  September 09, 2026 ID: 000154992

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  September 09, 2026 ID: 000185734

This article explains step by step how To Convert Untagged DATA Networks On Access Mode To VLAN tagged Interfaces After Upgrade And OS Conversion.
Updated:  September 09, 2026 ID: 000444848

During a PowerFlex Management Platform (PFMP)‑initiated firmware upgrade, the management network bond0 interface remains down. Restarting the legacy network service restores connectivity.
Updated:  September 09, 2026 ID: 000464100

The SCLI Truststore in PowerFlex serves as a repository of trusted digital identities, specifically storing trusted Certificate Authority (CA) certificates. These certificates are used to verify the authenticity of other components within the PowerFlex environment and to establish secure, authenticated communications, such as between the SCLI client and the Meta Data Manager (MDM). This can be used as a solution if you see the following message when trying to login to SCLI on the Primary MDM "Failure to connect to management system"
Updated:  September 08, 2026 ID: 000347478

PowerFlex disk devices are failing randomly or report errors on disk devices. ESXi reports errors on disk devices, and LSI raid controller errors (SCSI abort and reset commands).
Updated:  September 08, 2026 ID: 000283423

This article describes the Dell PowerFlex product limits and the system requirements for components for each consumption model. The product limits summarize the supported capabilities and system limits. Maximum and minimum values for key system components are dictated by the product limits.
Updated:  September 08, 2026 ID: 000502506

This article takes about the different error messages on NVDIMM-N and self healing and does it differ from RDIMMs and LRDIMMs.
Updated:  September 07, 2026 ID: 000052811

This article explains the command switch_cluster_mode to change the MDM cluster to 1 or 3 or 5 node cluster
Updated:  September 07, 2026 ID: 000502467

During maintenance operations on the PowerFlex Management Cluster (PFMC), the SDS node fails to exit and remains in Protected Maintenance Mode (PMM), as MDM rejects the request and returns the error SDS_MAINTENANCE_MODE_EXIT_FAILED with the message "The wrong maintenance mode type was chosen for this SDS".
Updated:  September 07, 2026 ID: 000501252

This article outlines various methods to identify versions in the PowerFlex family, including PowerFlex solutions and software only.
Updated:  September 07, 2026 ID: 000222560

This article shows How To determine why a virtual machine powered off or rebooted by reviewing log files and host details to identify guest shutdowns, user or API requests, HA resets or system faults.
Updated:  September 07, 2026 ID: 000205778

When a user deletes a PowerFlex volume backed VM and the compute/host and SDC node is unreachable, it fails.
Updated:  September 07, 2026 ID: 000058331

During normal use multiple devices in the PowerFlex system go into error state, and Data Unavailability (DU) happens.
Updated:  September 07, 2026 ID: 000051055

Unexpected MDM_DATA_DEGRADED events with no SDS_DISCONNECTED or SDS_RECONNECTED events
Updated:  September 07, 2026 ID: 000031516

PowerFlex SDSs with Samsung PM1733a NVMe SSDs running firmware 1.0.X or 1.1.X may experience intermittent drive dropouts. Elevated latency and slow I/O on affected drives can trigger cascading timeout failures, including Data Unavailability (DU) events, upgrade failures, and daily operation issues.
Updated:  September 04, 2026 ID: 000455462

When the PowerFlex Manager REST API gateway becomes unavailable, virtual machines running on Nutanix may start becoming inaccessible, resulting in client outages.
Updated:  September 04, 2026 ID: 000385318

A single slow SSD device may cause endless rebuilds and eventually a Data Unavailability (DU).
Updated:  September 03, 2026 ID: 000387366