Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

DCBx Error Messages

The following syslog messages appear when an error in DCBx operation occurs.

LLDP_MULTIPLE_PEER_DETECTED: DCBx is operationally disabled after detecting more than one DCBx
                                 peer on the port interface.
                              
LLDP_PEER_AGE_OUT: DCBx is disabled as a result of LLDP timing out on a DCBx peer interface.
DSM_DCBx_PEER_VERSION_CONFLICT: A local port expected to receive the IEEE, CIN, or CEE version
                                 in a DCBx TLV from a remote peer but received a different, conflicting DCBx version.
                              
DSM_DCBx_PFC_PARAMETERS_MATCH and DSM_DCBx_PFC_PARAMETERS_MISMATCH: A local DCBx port received
                                 a compatible (match) or incompatible (mismatch) PFC configuration from a peer.
                              
DSM_DCBx_ETS_PARAMETERS_MATCH and DSM_DCBx_ETS_PARAMETERS_MISMATCH: A local DCBx port received
                                 a compatible (match) or incompatible (mismatch) ETS configuration from a peer.
                              
LLDP_UNRECOGNISED_DCBx_TLV_RECEIVED: A local DCBx port received an unrecognized DCBx TLV from
                                 a peer.
                              