Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Running Offline Diagnostics

To run offline diagnostics, use the following commands.

For more information, refer to the examples following the steps.
  1. Place the unit in the offline state. EXEC Privilege mode offline stack-unit You cannot enter this command on a MASTER or Standby stack unit.
    • NOTE: The system reboots when the offline diagnostics complete. This is an automatic process. The following warning message appears when you implement the offline stack-unit command:
      Warning - offline of unit will bring down all the protocols and
                                                      the unit will be operationally down, except for running Diagnostics.
                                                      Please make sure that stacking/fanout not configured for Diagnostics execution.
                                                      Also reboot/online command is necessary for normal operation after the offline command is issued.
                                                      Proceed with Offline [confirm yes/no]:
                                                   
    Dell#offline stack-unit 0
                                        Warning - offline of unit will bring down all the protocols and
                                        the unit will be operationally down, except for running Diagnostics.
                                        Please make sure that stacking/fanout not configured for Diagnostics execution.
                                        Also reboot/online command is necessary for normal operation after the offline command is issued.
                                        Proceed with Offline [confirm yes/no]:yes
                                        Dell#
                                        
                                     
  2. Confirm the offline status. EXEC Privilege mode show system brief
    Dell#show system brief 
                                        
                                        Stack MAC : 00:1e:c9:de:03:7b
                                        
                                        --  Stack Info  --
                                        Unit  UnitType     Status         ReqTyp          CurTyp          Version     Ports
                                        ------------------------------------------------------------------------------------
                                        0   Management   offline        PE-FN-410S-IOA  PE-FN-410S-IOA  1-0(0-1862)  12     
                                        1   Member       not present                    
                                        2   Member       not present                    
                                        3   Member       not present                    
                                        4   Member       not present                    
                                        5   Member       not present                    
                                        
                                        Dell#
                                     

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"