    SmartOnLine SU3000RTXL3U - UPS ( rack-mountable ) - 3000 VA - UPS battery - 9 Output Connector(s) - 3 U - 19-inch

    Tripp Lite's SmartOnline SU3000RT3U on-line, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges. Multi-use form factor occupies only 3 rack spaces (3U) in standard 19 ...  Show More
    CAD $2,316.99
    Ships 10-26-2020
    Add to Cart
    Manufacturer part SU3000RTXL3U | Dell part A7022217 | Order Code a7022217 | TrippLite
    Compare

    SU3000RTXL3U SmartOnline® Double-Conversion Rack/Tower Sine Wave UPS with Expandable Runtime and Network Slot

    POWER PROTECTION AND EXPANDABLE BATTERY BACKUP
    for servers and network hardware

    This on-line, double-conversion UPS system protects critical network systems from damage, downtime and data loss.
    • True on-line, double-conversion operation delivers pure sine wave output, precise voltage regulation and isolation from power problems.
    • Expandable battery backup supports critical systems during outages.
    • Network slot supports optional remote access and network management.
    • USB and DB9 serial ports connect to computers for power management.
    • 2-year warranty and $250,000 insurance reflect commitment to reliability.
    SU3000RTXL3U SmartOnline® Double-Conversion Rack/Tower Sine Wave UPS with Expandable Runtime and Network Slot
    Why is this UPS a Good Investment? 4:06

    Why is this UPS a Good Investment?

    The success of your organization depends on critical information systems like servers and network hardware. If your critical systems don't have reliable power, employees can't work, communications go down, automated systems malfunction and productivity grinds to a halt. It would be nice if utility power was always reliable, but it isn't. Between severe weather, the aging electrical grid and hazards lurking inside your own walls, your servers and network hardware are under attack from power problems. Even a brief loss of power or a momentary surge can damage your equipment, corrupt your data, bring down your network and hurt your bottom line.

    The potential costs of downtime are alarming. Surveyed averages range from $1,167 per minute for mid-size businesses (IDC) to $7,908 per minute for larger operations (Ponemon Institute). For a tiny fraction of these costs, you can prevent damage, downtime and data loss by installing this SmartOnline UPS system. True on-line double conversion is the highest level of power protection available. It provides precise voltage regulation, delivers continuous sine wave output and isolates equipment from power problems.

    Common Applications

    Protect Mission-Critical Servers and Network Hardware
    Application Servers, Storage Servers, Database Servers, File Servers, Virtualization Servers, Proxy Servers, Web Servers, Cloud Platform Servers, Media Servers, VoIP Servers, Converged Infrastructure, Network Switches, PoE Switches, Firewalls, Network Appliances, Bridges, Gateways, Routers

    Protect Equipment with Active PFC Power Supplies
    Active PFC power supplies found in many devices require sine wave power.

    Expandable Battery Backup

    • Half-Load Runtime: This UPS system will support a 50% load (1200W) for up to 14 minutes using the included batteries.
    • Extended Runtime: This UPS system allows you to connect one or more optional external battery packs to provide additional backup runtime. Some external battery packs can also be daisy-chained, allowing you to scale runtime to match almost any application requirement.
    • Hot-Swappable Batteries: You can add or replace batteries without turning off the UPS system and disrupting the operation of connected equipment.

    On-Line, Double-Conversion Operation

    This UPS system provides the highest level of power protection available:
    • Continuous on-line, double-conversion operation provides precise voltage regulation and sine wave output. It isolates connected equipment from most power problems, including blackouts, brownouts, overvoltages, transient voltages surges, electromagnetic (EMI/RFI) line noise, harmonic distortion, electrical impulses and frequency variations.
    • Zero transfer time to battery prevents malfunctions and reboots of sensitive equipment potentially caused by the transition from line power to battery-derived power during outages.
    • Fault-tolerant automatic bypass maintains utility output and avoids downtime during a variety of fault and overload conditions.

    Flexible Management Options

    There are several ways to manage this UPS system:
    1. Use the front-panel LEDs for convenient local management.
    2. Use the USB port with your computer's built-in power management features.
    3. Use the USB or serial port with your computer and Tripp Lite's PowerAlert® software. PowerAlert provides enhanced features like automatic file saves, event notification, logging, advanced device control and an SNMP agent that supports centralized management. Select UPS models include a convenient CD-ROM, or you can download the latest version of PowerAlert for free at Tripp Lite's website.
    4. Install an optional network card to enable standalone network management via SNMP, Web, SSH or telnet. The network card has an Ethernet port and embedded interface, allowing you to access advanced monitoring, control and notification features without directly connecting the UPS system to a computer. The network card also supports connecting one or more optional sensors for remote temperature, humidity and contact closure monitoring. (Available network cards and sensors include TLNETCARD with TLNETEM sensor; WEBCARDLX with E2MT, E2MTDO, E2MTDI and E2MTHDI sensors; and SNMPWEBCARD with ENVIROSENSE sensor. Refer to each model for specific features.)
    This UPS system also has two switched outlet banks, allowing you to reboot locked devices remotely or turn off nonessential loads during extended outages to provide additional runtime.

    LED Control Panel

    Intuitive multicolor LEDs display a variety of helpful and important information:
    • During an outage, the battery meter displays the percentage level of battery charge remaining.
    • During normal operation, the load meter displays the equipment load as a percentage of maximum capacity.
    • Other diagnostic LEDs display several fault conditions (including wiring faults in the wall outlet) and warning conditions (including the need to recharge or replace the UPS system's internal battery). They also indicate UPS system operational status, including normal on-line operation, economy mode operation, bypass operation (due to fault or overload) or on-battery operation (due to a blackout or severe brownout).
    If you decide to install the UPS system in a tower configuration, you can rotate the control panel to match.

    Eco-Friendly Design

    • Economy Mode: This UPS system provides user-selectable economy mode operation to increase efficiency and cut operating costs. In economy mode, the UPS system suspends double conversion and operates with increased efficiency as long as input power quality is satisfactory. If input power quality becomes unsatisfactory, the UPS system immediately resumes double conversion until power quality returns to normal.
    • User-Replaceable Battery: This UPS system has a user-replaceable, recyclable battery, allowing it to remain in service instead of going to a landfill.
    • RoHS Compliance: This UPS system complies with the RoHS (Restriction of Hazardous Substances) Directive, limiting the use of hazardous substances in manufacturing.

    Dependable Service from an Industry Leader

    Service and Support
    • 2-Year Product Warranty: If this UPS system (including the internal battery) proves defective in material or workmanship within that period, Tripp Lite will repair or replace it at no charge.
    • $250,000 Insurance: Tripp Lite will repair or replace connected equipment damaged by surges – even lightning strikes!
    • Free Tech Support: Chicago-based, in-house tech specialists are available by phone, email and chat.
    Industry Leader
    • Over 90 Years: Founded in 1922, Tripp Lite has a long-established and proven track record of providing reliable products and responsive customer service.
    • Trusted Name: From the smallest office to the largest data center, customers worldwide trust Tripp Lite to power, protect, manage and connect valuable IT equipment.
    • Third-Party Safety Testing and ISO 9001 Certification

    Key Specifications

    Model: SU3000RTXL3U
    Load Capacity:
    3 kVA (2.4 kW)
    Power Factor: 0.8
    Nominal AC Input: 110V; 120V (50/60 Hz)
    Nominal AC Output: 110V; 120V (50/60 Hz)
    Output Voltage Regulation (Line Mode): +/- 2%
    AC Outlets: 4 x 5-15R; 4 x 5-15/20R; 1 x L5-30R
    Switched Outlet Banks: Two switchable four-outlet load banks
    Output Waveform (AC Mode): Pure Sine Wave
    Output Waveform (Battery Mode): Pure Sine Wave
    Input Cord: 10 ft. (3 m) Cord with L5-30P Plug
    Half-Load Runtime (Included Batteries): 14 min. (1200 W load)
    User-Replaceable Battery: Yes (RBC96-3U)
    Expandable Battery Runtime:
    Yes (Requires optional external battery pack)
    Compatible External Battery Packs:
    BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)
    Data Line Protection: Tel/Network (1 line)
    Communications: USB Port (HID-Compliant); Serial Port (DB9); Contact Closure; Network Slot; EPO
    Primary Form Factor: 3U Rack (Supports 4-post rack installation with included kit. Add 2POSTRMKITHD for 2-post rack installation. Add 2-9USTAND for tower installation.)
    Dimensions: 5.2 x 17.8 x 26 in. (13.2 x 45.2 x 66.1 cm)
    Unit Weight: 73.8 lb. (33.5 kg)
    Standards: UL 1778 (USA); CSA (Canada); NOM (Mexico); FCC A (EMI); RoHS
    Product Warranty (Worldwide): 2-Year Limited Warranty
    Connected Equipment Insurance (U.S., Canada and Puerto Rico): $250,000
    What's Included: UPS, 4-Post Rack Installation Kit, USB/Serial/EPO Cabling, Manual

    Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Actual products may differ slightly from photos. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. Runtime varies with load, battery condition and other factors. Go to Tripp Lite's website for more information, including complete warranty terms and conditions.

    Tripp Lite's SmartOnline SU3000RT3U on-line, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges. Multi-use form factor occupies only 3 rack spaces (3U) in standard 19 inch rackmount configuration. It includes tower stands and removable rack hardware to support tower and stacking applications. The 3kVA/2400 Watt UPS continuously converts incoming AC to DC, then back to sine wave AC output at 120 V. It removes harmonic distortion, fast electrical impulses and frequency fluctuations. True sine wave output and zero transfer time offers compatibility with all equipment types. Further, it also includes 9 outlets arranged in two individually switchable load banks. These outlet banks can be independently controlled via software interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipments.

    Quick Specs


    Device Type
    UPS - rack-mountable
    Rack Size
    19" - 3U
    Output Voltage
    AC 120 V ± 2%
    Power Capacity
    2.4 kW / 3000 VA
    Input Connectors
    1 x power NEMA L5-30
    Output connectors
    4 x power NEMA 5-15 ¦ 4 x power NEMA 5-20 ¦ 1 x power NEMA 5-30
    Battery Form Factor
    Plug-in module
    Run Time (Up To)
    5 min at full load
    Colour
    Black
    Dimensions (WxDxH)
    45 cm x 66 cm x 13.3 cm
    Manufacturer Warranty
    2-year warranty

    General


    Device Type
    UPS - rack-mountable
    Battery Enclosure Type
    Plug-in module
    Height (Rack Units)
    3U
    Rack Size
    19"
    Colour
    Black

    Power Device


    UPS Technology
    On-line
    Input Voltage Range
    AC 85 - 138 V
    Frequency Provided
    50/60 Hz
    Frequency Required
    50/60 Hz
    Input Connectors
    1 x power NEMA L5-30
    Power Output Connectors Details
    • 4 x power NEMA 5-15
    • 4 x power NEMA 5-20
    • 1 x power NEMA 5-30
    Output Voltage
    AC 120 V ± 2% - 50/60 Hz
    Power Capacity
    2.4 kW / 3000 VA
    Output Waveform
    Sinewave
    Surge Suppression
    Yes
    Circuit Protection
    Circuit breaker

    Battery


    Voltage Provided
    72 V
    Run Time (Up To)
    5 min at full load
    Recharge Time
    4 hours

    Expansion / Connectivity


    Interfaces
    1 x management (RS-232) - 9 pin D-Sub (DB-9)
    Expansion Slots
    1 (total) / 1 (free) x Expansion Slot

    Miscellaneous


    Cables Included
    • Power cable 3.1 m
    • Network cable - external - 1.8 m
    Rack Mounting Kit
    Included
    Equipment Protection Value
    250000 US Dollars
    Features
    Emergency power off, LED display
    Compliant Standards
    FCC Class A certified, UL, cUL

    Software / System Requirements


    Software Included
    TrippLite PowerAlert

    Manufacturer Warranty


    Service & Support
    Limited warranty - 2 years

    Environmental Parameters


    Humidity Range Operating
    0 - 95%

    Dimensions & Weight


    Width
    45 cm
    Depth
    66 cm
    Height
    13.3 cm

    Ratings & Reviews


    Support

    Dell Support

    From drivers and manuals to diagnostic tools and replacement parts, Dell Product Support has you covered.

    Compare Products ()

    Add the products you would like to compare, and quickly determine which is best for your needs.
    Add the products you would like to compare, and quickly determine which is best for your needs.