Article Number: 000130637
Alert ID | XMS_DP_HALT_AND_VAULT_STATE_HALT_IN_PROG |
Alert Text | DP halt process is in progress |
Error Code | (0x0030C905) |
Description | Data Path has detected that both MTc drives from the same pair were lost, starting a halt and vault process. When this alert is raised Read Write I/O access is blocked. |
Resolution | Cause Connectivity to both MTc drives is lost, might be due to link/Hardware issue. Solution Wait until Data Path finishes Halt & Vault, once it's done, check for MTc drives state, if they are failed, replace them. If the drives are healthy or the issue remains after replacement, contact technical support for further assistance. |
Alert ID | XMS_DP_HALT_AND_VAULT_STATE_UNVAULT_FAILED |
Alert Text | Data Path unvault process failed |
Error Code | (0x0030C904) |
Description | Following Halt & Vault event, Data Path encountered Software/Hardware error when trying to unvault LOG image from raid into the MTc drives. When this alert is raised Read Write I/O access is blocked. |
Resolution | Cause Software/Hardware issues prevent from reading all the vaulted data from Raid into the MTc drives. Solution Data Path will try to Recover itself using the data it was able to vault/unvault, in case all is recovered, it will open gates. If the self-Recovery is not successful, the system will remain in Recovery mode and the gates will not open. In this case, contact technical support for further assistance. |
Alert ID | XMS_DP_HALT_AND_VAULT_STATE_VAULT_IN_PROG |
Alert Text | Data Path vault process is in progress |
Error Code | (0x0030C906) |
Description | Data Path has detected that both MTc drives from the same pair were lost, starting a halt and vault process. When this alert is raised Read Write I/O access is blocked. |
Resolution | Cause Connectivity to both MTc drives is lost, might be due to link/Hardware issue. Solution Wait until Data Path finishes Halt & Vault, once it's done, check for MTc drives state, if they are failed, replace them. If the drives are healthy or the issue remains after replacement, contact technical support for further assistance. |
Alert ID | DATA_PATH_LOG_DATA_TIER_OFFLINE DATA_PATH_LOG_METADATA_TIER_OFFLINE |
Title | Log data or metadata tier offline in PowerStore |
Error Code | (0x00200401) (0x00200501) |
Description | An NVRAM pair has gone offline, causing the data and metadata log tiers used to go offline. The system will be halted, and the data and metadata caches will be de-staged to the vault. The data path will not start until the NVRAM drives are restored. During system startup, the caches will be restored from the vault and normal operation will resume. Note: These alerts may cause loss of Read Write I/O access. |
Resolution | Cause Both NVRAM drives in a mirrored pair used to store the log data tier and log metadata tier are faulty. Solution Contact technical support for assistance. |
PowerStore
08 Dec 2021
3
Solution