PowerEdge: How to Configure and Change FX2/FX2S IO Aggregator Switch Programmable MUX Modes
Summary: This article explains what Programmable MUX mode is and how to configure and change to that mode from the default standalone mode.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Objectives
- Overview
- Configuring and Changing to Programmable MUX (PMUX) mode
Overview
IOA PMUX is a mode that provides flexibility of operation with added configurability. This is done by creating multiple LAGs, configuring VLANs on uplinks and the server side, configuring data center bridging (DCB) parameters, and so forth.
By default, IOA starts up in IOA Standalone mode. You can change to PMUX mode by running the following commands and then reloading the IOA. After the IOA reboots, the IOA operates in PMUX mode. PMUX mode supports both stacking or VLT operations.
Configuring and Changing to Programmable MUX (PMUX) mode:
| Commands | Parameters |
FX2/FX2S_CMC$ connect switch-1 |
SSH into the IP address of the CMC on the FX2/FX2S chassis, and run the command to connect to the IOA. |
Login: username |
Log in to the IOA switch and view the next-boot mode. |
Dell# configure |
Enter configuration mode. Change IOA mode to PMUX mode. |
Dell# delete startup-config |
Delete the startup configuration file. |
Dell# reload |
Reboot the IOA by entering the reload command. |
Dell# show system stack-unit 0 iom-mode |
Verify the current functional mode after switch boots. |
Affected Products
PowerEdge FX2/FX2s, PowerEdge M IO AggregatorArticle Properties
Article Number: 000121882
Article Type: How To
Last Modified: 05 Jun 2025
Version: 8