Isilon OneFS: Front panel LED does not deactivate after event group resolves
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
A node's front panel LED will not deactivate itself after an event group has resolved itself.
The event group will show as ended in WebUI or isi event list, but the LED will remain amber on a node's front panel.
This issue can occur on the following versions of OneFS:
OneFS 8.0.0.0 through 8.0.0.6
OneFS 8.0.1.0 through 8.0.1.2
OneFS 8.1.0.0 through 8.1.0.2
OneFS 8.1.1.0
Cause
This issue is caused by a problem in the CELOG service and will be fixed in a future release.
Resolution
When this issue is resolved it will be noted in the OneFS release notes for the 8.0.0, 8.0.1, 8.1.0 and 8.1.1 release families.
To work around this issue, this one-line for loop can be run on the cluster's console, by root, to deactivate the LED:
To work around this issue, this one-line for loop can be run on the cluster's console, by root, to deactivate the LED:
for i in $(isi_nodes %{id}); do rm -r /ifs/.ifsvar/db/celog_analysis/led/$i/*; done