PowerProtect Data Manager Appliance DM5500: "Mandatory uplinks in PCIeSlot 1:1/PCIeSlot 4:1 for appliance are not connected…"

Resumen: This KB covers an issue seen during the deployment phase where the PowerProtect Data Manager Appliance shows the following Critical Warning: : Initial network configuration screen shows the message "Mandatory uplinks in PCIeSlot 1:1/PCIeSlot 4:1 for appliance are not connected. Make sure required uplinks are connected to network switch with appropriate cables." ...

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

The following error maybe seen on the PowerProtect Data Manager Appliance UI upon initial login:

Mandatory uplink requirement warning


This issue may occur if you do not use same speed SFPs for all four uplinks. We do not support a mixture of copper and optical connections as well. 

DM5500 Port Layout
Network req

Four network ports are required for standard installation. Two ports are used for the customer management IP address, and two ports are used for the data uplinks to the public customer network.
  • Port 1 on the LOM PCIe slot 1 and port 1 in PCIe slot 4 are the customer management IP ports and should go to different switches for improved reliability and fault tolerance.
  • Port 2 on the LOM PCIe slot 1 and port 2 in PCIe slot 4 are the uplink ports used for data traffic and should go to different switches.

The following table shows the combinations of NIC ports on the DM5500, depending on how the customer configures the HBAs. A maximum of six optical ports and ten copper ports are available.
image.png
NOTE: In the above table, the row 1 on columns LOM (PCIe slot 1) and (PCIe slot 4) respectively state that either two 10 GbE SFP28 or two 25 GbE SFP28 are supported. If you choose 10 GbE SFP28 for the two ports on PCIe slot1, then you must go with the same 10 GbE SFP28 on the PCIe slot4. The same statement stands true for 25 GbE SFP28s as well. 


Causa

The following could be the causes of this issue:
  • If you use a mix of 10 GbE and 25 GbE SFPs, that would cause this problem
  • All four uplinks should have the same speed
  • We do not support a mix of Copper and Optical connections

Resolución

DM5500 Appliance does not support a mix of 10 GbE and 25 GbE SFPs on the uplink ports. All 4 uplink ports must be connected to either 10 GbE SFPs or 25 GbE SFPs. 
 
NOTE:
  • All four uplinks should have the same speed
  • We do not support a mix of Copper and Optical connections

Productos afectados

PowerProtect Data Manager Appliance, PowerProtect DM5500
Propiedades del artículo
Número del artículo: 000211263
Tipo de artículo: Solution
Última modificación: 31 ago 2023
Versión:  6
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.