PowerMax: 2500 and 8500: Error Code: 3F10.12 - SDMA Locate Failure
Summary: SDMA Locate Failure occurs on PowerMax 2500 and 8500.
Symptoms
Products:
- PowerMax 8500
- PowerMax 2500
- VMAX4
Feature:
- LREP
Software:
- PowerMaxOS 10.0.X.X
- PowerMaxOS 10.1.0.1
Error codes:
Error code: 82.3F10.12 - SDMA Locate Failure Error code: xx3C.14 Error code: 423E.14
Cause
The RSVD Node always indicates the latest version of the track for a device involved in LREP. When there is a write to a track involving LREP, and we must push the old data to RDP.
The TID SEQ# is updated to match the Device Seq# and the old RSVD Node is pushed to RDP. A new RSVD node is assigned with the same Seq#. Therefore, the RSVD Node Seq# should always match the TID Seq# and we should only have one RSVD Node for a track.
The 3F10.12 error occurs when the RSVD node SEQ# does not match the TID SEQ#. We have seen cases where the RSVD node SEQ# is greater or less than the TID SEQ#.
Resolution
The issue is planned to be addressed in a future hotfix that is available from Q1 24 patch release. Contact Dell Technical Support or your service representative and mention this article ID for assistance.