Article Number: 000218645
Fabric OS 9.1.1c
The outputs show errors when running an inline command from a UNIX or Linux server. The command stops responding when probing a different logical Switch FID on the same chassis. Example:
[hosttest@VM1234 ~]$
[hosttest@VM1234 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@aa.bb.cc.dd's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
/etc/ssh_inline_profile: line 25: FUNCNEST: readonly variable
Appl Primary/Secondary Versions
------------------------------------------
FOS v9.1.1c
v9.1.1c
---------------------------------------------------
"firmwareshow" on FID 44:
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@10.60.23.25's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
Appl Primary/Secondary Versions
------------------------------------------
FOS v9.2.0a
v9.2.0a
---------------------------------------------------
"firmwareshow" on FID 44:
[hosttest@VM3198 ~]$
Upgrade to Fabric OS 9.2.0b or later.
Run the commands directly on the switch.
Connectrix, Connectrix B-Series
Connectrix B-Series Fabric OS 9.X
15 Nov 2023
3
Solution