PowerProtect Data Manager:将 SQL 资产添加到策略失败,ACS0001

Summary: PowerProtect Data Manager (PPDM) 设备用于保护 SQL 数据库资产。将 SQL 资产添加到保护策略失败,并显示错误代码 ACS0001。配置作业无法验证与 Data Domain 的存储连接。从备份客户端到 Data Domain 数据接口的端口通信被阻止。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

备份管理员将 SQL 资产添加到 PPDM 中的保护策略。配置作业失败,并显示以下错误:

Unable to verify the DD Boost credentials for access to the Data Domain storage unit on Data Domain host.

SQL 主机上的配置作业日志显示ACS0001错误并显示存储验证失败:

AddOnConfiguration_8344bfec3ff65225-04Sep2026_10_52_07_684978-42521788544978.571992.log: [2026-09-04 18:02:58,554 GMT| 2026-09-04 11:02:58,554153 Yukon Standard Time| ADDONCONFIGURATION_8344BFEC3FF65225| PID-4252| TID-7028| INFO| TraceContext-TRACE_ID:8344bfec3ff65225;EXEC_ID:88c8c6ea909d4faa] C:\Program Files\DPSAPPS\AgentService\tmp\_MEI74082\JobManager\JobManager.py-_runProcess()-Line 1686- The /v1/agent/configuration-sessions job returns - Errors:[],
Response:{'status': 'FAILURE', 'errorMessage': '', 'remediation': '', 'output': '', 'errorCode': 'ACS0001', 'alertArguments': [{'argumentName': 'StorageUnit', 'argumentValue': '/StorageUnit-Name/Storage-Folder'}, {'argumentName': 'DDHost', 'argumentValue': '192.168.0.100'}], 'vendorSpecificErrorMessage': '', 'stats': [{'id': '1ebc9817-b915-4064-9849-2a13ff1e3f8d', 'status': 'FAILURE', 'errorCode': 'ACS0001', 'errorMessage': '', 'warningMessage': '', 'remediation': '', 'vendorSpecificErrorMessage': '', 'alertArguments': [{'argumentName': 'StorageUnit', 'argumentValue': '/StorageUnit-Name/Storage-Folder'}, {'argumentName': 'DDHost', 'argumentValue': '192.168.0.100'}], 'steps': [{'name': 'Validating the storage connection for storage unit StorageUnit-Name', 'status': 'STEP_FAILED', 'startTime': '2026-09-04T17:52:10Z', 'endTime': None, 'duration': None

The /var/log/brs/adm/adm.log 在 PPDM 设备上,显示配置会话已完成,ACS0001:

adm.log: 2026-09-04T18:04:00.233Z INFO [] [adm-common-session-monitoring-interceptor-14] [00000000-0000-4000-a000-000000000000][][][TRACE_ID:8344bfec3ff65225;EXEC_ID:88c8c6ea909d4faa][] [c.d.p.a.n.d.e.b.s.m.MonitorTaskProgress.setTaskApiForAgentCall(344)] - Session completed. Agent Service Task API response received from host 192.168.0.101 for sessionId 1038e3f85e0249fd9aa33e9a32d2637f with context id:003a37ba-734f-4327-9054-ba97a58663e1, Task Api response:class TaskOutput {
    nextPageToken: null
    content: [class Operation {
        id: 1ebc9817-b915-4064-9849-2a13ff1e3f8d
        type: CONFIGURATION
        assetNaturalId: null
        status: FAILURE
        parentSessionId: 1038e3f85e0249fd9aa33e9a32d2637f
        errorCode: ACS0001
        errorMessage: 
        remediation: 
        result: null

Cause

从备份客户端到 Data Domain 数据接口 IP 地址的端口通信被阻止。SQL 代理在策略配置期间验证存储连接。验证需要在端口 111、2049 和 2052 上连接到 Data Domain。当这些端口被阻止时,验证会失败并显示ACS0001。

错误日志中的 Data Domain IP 地址标识了无法访问的特定接口。

Resolution

为属于 Data Domain 的所有地址打开从备份客户端到 Data Domain 的端口 111、2049、2052。具体而言,请确保在日志消息中找到的 IP 地址已从资产源主机打开端口。

所需端口可在适用于当前版本的《PowerProtect Data Manager 安全配置指南》中找到。您可以通过在以下知识库文章中选择所需的版本来查找指南:

PowerProtect Data Manager:信息中心产品文档和信息

请参阅 PowerProtect Data Manager 安全配置指南 —> 网络安全 —> 端口使用情况。 

Affected Products

PowerProtect Data Manager
Article Properties
Article Number: 000507907
Article Type: Solution
Last Modified: 16 أيلول 2026
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.