ViPR SRM Storage M-R VPLEX missing Director Port Performance Counters after upgrade
Summary: ViPR SRM, Storage M&R (VPLEX) missing Director Port Performance Counters after upgrade.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Storage M&R (VPLEX) missing Director Port Performance Counters after upgrade.
- Storage M&R (VPLEX) missing Director Port Performance Counters after upgrade to SRM 4.2 or SRM 4.2.1.
- ViPR SRM Dell VPLEX Solution pack missing Director Port Performance Counters after upgrade to SRM 4.2 or SRM 4.2.1
Cause
In VPLEX, every director has a different header format, since Dell optimized reading headers, either A or B ports performance goes missing.
Resolution
To address this issue, revert the optimization pertaining to reading the header format.
Steps to revert the optimization:
- Stop VPLEX Collector service
- Rename file
get-director-data.pytoget-director-data.py-origon VPLEX Collector Host in location/opt/APG/Collecting/Stream-Collector/emc-vplex/conf/ - Copy script
get-director-data.pyto VPLEX Collector Host to location/opt/APG/Collecting/Stream-Collector/emc-vplex/conf/ - Rename file
get-director-data.pytoget-director-data.py-origon VPLEX Cluster Host in location/home/service/ - Copy script
get-director-data.pyto VPLEX Cluster Host to location/home/service/ - Copy the script
get-director-data.pyon all VPLEX cluster hosts. - Copy the script
get-director-data.pyon all VPLEX Collector Hosts. - Start VPLEX Collector service
Note: If the discovery User in SRM is not "service," then the Script Path on the VPLEX Clusters is
/home/<User>
Article Properties
Article Number: 000167991
Article Type: Solution
Last Modified: 14 جمادى الآخرة 1447
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.