PowerStore Alerts: Drive Evict State
Summary: PowerStoreOS 4.3.0 and above introduce a new feature to allow automatic eviction or manual eviction of drives. Evicting a drive allows to proactively copy the data from the evicted drive to a newly added drive. There should be minimal impact to the customer during this process. The eviction process allows for a faster recovery from a drive that is about to fail as the system can endure another drive failure (unlike with standard drive rebuild where we cannot lose another drive). PowerStoreOS automatically attempts to evict drives that reach 95% wear level to allow for faster recovery. The eviction process can only be performed on a single drive at a time, and it can be cancelled before the new drive is added and eviction (data copy) is actually started. ...
Symptoms
When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution that is provided, check the technical support contact options.
Cause
Cause is self-explanatory in the Alert Texts mentioned in Resolution section.
Resolution
For Drive eviction procedure, refer KB 222359.
| Alert ID | XMS_DRIVE_EVICT_STATE_SYSTEM_REQUEST_TO_EVICT | ||||||||||||||||||||||
| Alert Text | The system has set the drive in bus %(bus_num) encl %(encl_num) slot %(enclosure_slot) to be evicted because of high wear. The eviction process could not start because of %(pause_reason). | ||||||||||||||||||||||
| Error Code | (0x00306402) | ||||||||||||||||||||||
| Description | At 95% drive wear level, PowerStoreOS automatically initiates the eviction process for the drive. Due to a known reason the eviction process did not start. | ||||||||||||||||||||||
| Alert ID | XMS_DRIVE_EVICT_STATE_CUSTOMER_REQUEST_TO_EVICT | ||||||||||||||||||||||
| Alert Text | The user has set the drive in bus %(bus_num) encl %(encl_num) slot %(enclosure_slot) to be evicted. The eviction process could not start because of %(pause_reason). | ||||||||||||||||||||||
| Error Code | (0x00306403) | ||||||||||||||||||||||
| Description | User chose to evict a drive. Due to a known reason the eviction process did not start. | ||||||||||||||||||||||
| Resolution |
Cause
|
| Alert ID | XMS_DRIVE_EVICT_STATE_EVICTING_PAUSED | ||||||||||||||
| Alert Text | Eviction for drive in bus %(bus_num) encl %(encl_num) slot %(enclosure_slot) is paused due to an unexpected issue preventing the eviction process from proceeding. Reason: %(pause_reason). | ||||||||||||||
| Error Code | (0x00306405) | ||||||||||||||
| Description | Drive is in the process of eviction. Due to a known reason the eviction process is paused. | ||||||||||||||
| Alert ID | XMS_DRIVE_EVICT_STATE_EVICTING_ERROR | ||||||||||||||
| Alert Text | The eviction of drive in bus %(bus_num) encl %(encl_num) slot %(enclosure_slot) has stopped, reason %(pause_reason). | ||||||||||||||
| Error Code | (0x00306406) | ||||||||||||||
| Description | Drive is in the process of eviction. Due to a known reason the eviction process has entered an error state. | ||||||||||||||
| Resolution |
Cause
|
| Alert ID | XMS_DRIVE_EVICT_STATE_EVICTING_ABORTED |
| Alert Text | The eviction of drive in bus %(bus_num) encl %(encl_num) slot %(enclosure_slot) has been aborted. |
| Error Code | (0x00306407) |
| Description | A drive is in the process of eviction, Dell support decided to abort the process due to an issue in the appliance. |
| Resolution | Cause This alert indicates the eviction process was aborted by Dell service personnel. Solution Contact Dell Technical Support for assistance |
Additional Information
FAQ:
- A drive has been successfully evicted, what happens next?
Once eviction process completes, the evicted drive will be marked as FAILED (with reason: Evicted) and needs to be removed. - The drive under eviction failed during the eviction process, what happens next?
If the drive under eviction fails during the eviction process, eviction will be PAUSED, and after 5 minutes the rebuild starts. as the rebuild starts, the eviction process completes successfully, since the copy-to mechanism is no longer relevant. the new drive is being rebuilt.