Avamar NetWorker or PPDM WC IDRAC 9 boot disk order issue disk 0 and disk 1 BMR failing
Shrnutí: The customer is using an A:\ drive USB to load disk drivers or the ISO for Avamar, NetWorker, or PowerProtect Data Manager BMR. The BMR process needs the C:\ to be disk 0 after drivers are loaded or we receive a Critical volume error. The USB disk is loaded together with the Virtual CD iso image. ...
Tento článek se vztahuje na
Tento článek se nevztahuje na
Tento článek není vázán na žádný konkrétní produkt.
V tomto článku nejsou uvedeny všechny verze produktu.
Příznaky
The Customer sees the following when performing the BMR process.
This is confirmed with the Diskpart command as shown below when the USB disk is loaded together with the Virtual CD iso image.
Disk 0 is expected to be the C:\ drive with the proper size.

This is confirmed with the Diskpart command as shown below when the USB disk is loaded together with the Virtual CD iso image.
Disk 0 is expected to be the C:\ drive with the proper size.

Příčina
The iDRAC loads the Virtual media as a combination of the Virtual CD with the Bootable ISO image and the USB disk that may be needed for drivers.
Řešení
Here are the steps done to work around the USB presenting as "disk 0".
We booted off the CD virtual media in the iDRAC.
Wait on working through the Wizard and perform steps in the dos administrator window.
After booting copy the needed files for the driver files to the "x:\" into a named folder from the attached virtual media.
Now select the "disconnect virtual media" button shown below in the iDRAC window.
The "d:\" cd drive and the USB drive get removed but since the BMR runs in a memory drive "x;" and should remain with your driver files.
The Diskpart, List disk should show empty no "disk 0" and the customer can then proceed to run the BMR wizard and load the raid driver.
We booted off the CD virtual media in the iDRAC.
Wait on working through the Wizard and perform steps in the dos administrator window.
After booting copy the needed files for the driver files to the "x:\" into a named folder from the attached virtual media.
Now select the "disconnect virtual media" button shown below in the iDRAC window.
The "d:\" cd drive and the USB drive get removed but since the BMR runs in a memory drive "x;" and should remain with your driver files.
The Diskpart, List disk should show empty no "disk 0" and the customer can then proceed to run the BMR wizard and load the raid driver.
Dotčené produkty
iDRAC9, Avamar Client, Avamar Client for Windows, NetWorker Module for Microsoft, PowerProtect SoftwareVlastnosti článku
Číslo článku: 000215725