PowerProtect Data Manager:复制失败,并显示错误“Err:5009 文件复制操作失败(NFS:“I/O”错误)”

Summary: PowerProtect Data Manager:复制失败,并显示错误“Err:5009 文件复制操作失败(NFS:“I/O”错误)”

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PPDM 日志:
Err: 5009 file-copy operation failed (nfs: "I/O" error)

DD 日志:
Failed to do a filecopy, err = [5029: rpc operation/function failure, ddr/repl/lrepl_client.c, filecopy_handle_scaleout, 14606]
端口 2051 在 DD 之间打开。PPDM 的复制过程达到 99%,但会传输 0 字节数据,直到重新绑定 20 次后失败。 

Cause

交换机 MTU:1500
DD NIC MTU:9000

Resolution

确保交换机上的 MTU 与 DD 相同