PowerProtect Data Manager:複製失敗,並顯示錯誤「Err:5009 檔案複製作業失敗 (NFS:「I/O」錯誤)」
Summary: PowerProtect Data Manager:複製失敗,並顯示錯誤「Err:5009 檔案複製作業失敗 (NFS:「I/O」錯誤)」
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
PPDM 記錄:
DD 記錄:
Err: 5009 file-copy operation failed (nfs: "I/O" error)
DD 記錄:
Failed to do a filecopy, err = [5029: rpc operation/function failure, ddr/repl/lrepl_client.c, filecopy_handle_scaleout, 14606]連接埠 2051 在 DD 之間開啟。從 PPDM 的複製程序達到 99%,但傳輸的資料為 0 位元組,直到經過 20 次連接失敗為止。
Cause
交換器 MTU:1500
DD NIC MTU:9000
DD NIC MTU:9000
Resolution
確定交換器上的 MTU 與 DD 相同
Affected Products
PowerProtect Data ManagerArticle Properties
Article Number: 000225799
Article Type: Solution
Last Modified: 11 Dec 2025
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.