NetWorker vProxy backup mislukt met "RPC error: Kan geen verbinding maken met host " en "Err: 5037-Kan IP-adres van host niet oplossen "

Summary: De integratie van NetWorker VMware Protection (NVP) is geconfigureerd met de vProxy Appliance. De vProxy-implementatie had enkele problemen met naamresolutie en DNS. De back-ups van de virtuele machine (VM) voor sommige virtuele machines mislukken met een foutmelding over ongeldige naamresolutie. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

In het bestand /opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:YYYY-MM-DDTHH:MM:SSZ ERROR:  [1268:7F4794001E30] ddp_connect_with_config_internal() failed, Hostname: 110DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:YYYY-MM-DDTHH:MM:SSZ ERROR:  [1268:7F4794001E30] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T07:08:43Z ERROR:  [1268:7F4778001C80] ddp_connect_with_config_internal() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T07:08:43Z ERROR:  [1268:7F4778001C80] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
---- Skipping Lines ----
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T13:59:20Z ERROR:  [1268:7F4778001C80] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T14:06:29Z INFO:   [1268:7F476C001C80] ddcl_nfs_open_tcp - Timed out trying to resolve the hostname: DD###_T4
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T14:15:29Z ERROR:  [1268:7F476C001C80] ddp_connect_with_config_internal() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T14:15:29Z ERROR:  [1268:7F476C001C80] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0

Van /nsr/logs/daemon.raw:
71193 MM/DD/YYYY HH:MM:SS AM  0 0 0 4988 4616 0 my_networker_server nsrd NSR info Media Info: Failed to start nsrsnmd on host my_storagenode_name, error `RPC error: Failed to connect to host 'my_storagenode_name': Remote system error - No connection could be made because the target machine actively refused it.
 

Cause

Probleem met naamresolutie op vProxy hostniveau

Resolution

Voeg handmatig het IP-adres, FQDN, korte naam van vCenter, Data Domain, NetWorker en Storage Node toe in /etc/hosts van vProxy Host.

Start nu vProxy VM back-ups.
  1. Meld u aan bij de vProxy PuTTY-sessie als beheerder en schakel vervolgens over naar root:
sudo su - root
  1. Voer de volgende opdracht uit om een /etc/host-vermelding te maken
# echo "IP_of_vCenter FQDN_of_vCenter ShortName_of_vCenter" >> /etc/hosts
MONSTER:
# echo "10.10.10.10 myvcenter.abc.com myvcenter" >> /etc/hosts
# echo "IP_of_DD FQDN_of_DD ShortName_of_DD" >> /etc/hosts
# echo "IP_of_NWServer FQDN_of_NWServer ShortName_of_NWServer" >> /etc/hosts
# echo "IP_of_StorageNode FQDN_of_StorageNode ShortName_of_StorageNode" >> /etc/hosts

Products